Overview
55
Perfect Pick® Cortex™ Operator Manual
OPEX Corporation
In terms of the hand-off, which occurs at the OPEX induction zone as well as
the integrator’s first outbound zone, there are two methods:
•
Method 1 - an extra sensor in the Induction zone (fed back to Integrator) +
sensor in first Integrator outbound zone (Zone 14 on the majority of installs,
OPEX controls that sensor). This is the method described above, and if
clearing a jam in the Induction zone, one sensor has to be covered.
•
Method 2 - A hand-off relay is used to signal the status of the OPEX
induction zone, controlled via software. This is effectively a “ready-to-
receive” signal. When the Induction zone is not interrupted and no
container is present, this output is high, which switches a small relay in a
stand-alone enclosure (#6095600). Integrator is free to run their control
signal through the relay contact (this can be DC or AC). An addition to this
relay box is a safety relay, which can be used for safety integration. When it
is required to shut down the OPEX Workstation and conveyor with the Inte-
grator’s section of conveyor, there are also provisions for a signal from the
Integrator, done in a similar manner for communication in both directions.
When issues are seen with the Induction zone, if this method is used, the
relay should be checked (it has a green LED which should be “ON” when
the induction zone sensor is unblocked).
For the Outbound integration, it may still include an extra sensor or may act
in a similar manner with the Integrator, providing a relay contact with a
“ready-to-receive” signal.
3.6.1.2. Transition sensors
These sensors are between the zones and are used to shut off the motors
once a container has made it into the required zone. These sensors are in the
walls of the conveyor and also under the conveyor at the work station.
Содержание Perfect Pick Cortex
Страница 10: ...10 Introduction Perfect Pick Cortex Operator Manual OPEX Corporation This page is intentionally blank...
Страница 40: ...40 Safety Perfect Pick Cortex Operator Manual OPEX Corporation This page is intentionally blank...
Страница 56: ...56 Overview Perfect Pick Cortex Operator Manual OPEX Corporation This page is intentionally blank...
Страница 79: ...Operation 79 Perfect Pick Cortex Operator Manual OPEX Corporation Figure 4 25 Press the Container button...
Страница 110: ...110 Operation Perfect Pick Cortex Operator Manual OPEX Corporation This page is intentionally blank...
Страница 126: ...126 Troubleshooting Perfect Pick Cortex Operator Manual OPEX Corporation This page is intentionally blank...
Страница 127: ...Perfect Pick Cortex Operator Manual G Glossary G 1 List of Acronyms 128 G 2 List of Terms 129...
Страница 132: ...132 Glossary Perfect Pick Cortex Operator Manual OPEX Corporation This page is intentionally blank...
Страница 134: ...134 Perfect Pick Cortex Operator Manual OPEX Corporation...