Chapter 7:
Alerts and Logging
164
Console Server & RIM Gateway User Manual
noAuthNoPriv
No authentication or encryption.
authNoPriv
Authentication only. An authentication protocol (SHA or MD5)
and password will be required.
authPriv
Uses both authentication and encryption. This is the highest level
of security and requires an encryption protocol (DES or AES) and
password in addition to the authentication protocol and
password.
o
Complete the
Username.
This is the Security Name of the SNMPv3 user sending the message. This field is
mandatory and must be completed when configuring the
console server
for SNMPv3.
o
An
Authentication Protocol
(SHA
or
MD5
) and
Authentication Password
must be given for a Security
Level of either
authNoPriv
or
authPriv
. The password must contain at least 8 characters to be valid.
o
A
Privacy
Protocol
(
DES
or
AES
) must be specified for the
authPriv
level of security to be used as the
encryption algorithm. AES is recommended for stronger security. A password of at least 8 characters must be
provided for encryption to work.
Click
Apply
Note
Console servers with V3.0 firmware (and later) also embed the
net-snmpd
daemon which can accept SNMP
requests from remote SNMP management servers and provides information on serial port and device status (refer
Chapter 15.5
for more details).
Console servers with firmware earlier than V3.3 could only configure a Primary SNMP server from the
Management Console. Refer
Chapter 15.5 f
or details on configuring the
snmptrap
daemon to send
traps/notifications to multiple remote SNMP servers.
7.5.4 Send Nagios Event alerts
To notify the central Nagios server of Alerts, NSCA must be enabled under
System: Nagios
and Nagios must be enabled
for each applicable host or port under
Serial & Network: Network Hosts
or
Serial & Network: Serial Ports
(refer
Chapter 10).
Note:
In a CMS or VCMS centrally managed environment you can check the Nagios alert option. On the trigger
condition (for matched patterns, logins, power events and signal changes) an NSCA check "warning" result will be
sent to the central Nagios server. This condition is displayed on the Nagios status screen and triggers a
notification, which can then cause the Nagios central server itself to send out an email or an SMS, page, etc.
7.6
Logging
The
console server
can maintain log records of auto-response events and log records of all access and communications
events (with the
console server
and with the attached serial, network and power devices).
A log of all system activity is also maintained by default, as is a history of the status of any attached environmental
monitors.
7.6.1
Log storage
Before activating
any
Event, Serial, Network or UPS logging, you must specify where those logs are to be saved. These
records are stored off-server or in the ACM/IM gateway USB flash memory.
Select the
Alerts & Logging: Port Log
menu option and specify the
Server Type
to be used, and the details to
enable log server access
Содержание ACM5000
Страница 3: ......
Страница 10: ...Table of Contents 10 Console Server RIM Gateway User Manual...
Страница 11: ......
Страница 94: ...Chapter 5 Firewall Failover and Out of Band 94 Console Server RIM Gateway User Manual...
Страница 119: ......
Страница 149: ......
Страница 191: ......
Страница 205: ......
Страница 225: ......
Страница 303: ......
Страница 313: ......
Страница 323: ......