Chapter 4: Serial Port, Device and User Configuration
72
Console Server & RIM Gateway User Manual
To add a new network connected Managed Device:
T he
Administrator
adds a new network connected Managed Device using
Add Host
on the
Serial&Network:
Network Host
menu. This automatically creates a corresponding new Managed Device (as covered in
Section
4.4 - Network Hosts)
When adding a new network connected RPC or UPS power device, you set up a Network Host, designate it as
RPC or UPS, then go to
RPC Connections
(or
UPS Connections
) to configure the relevant connection. Again
corresponding new Managed Device (with the same Name /Description as the RPC/UPS Host) is not created until
this connection step is completed (refer
Chapter8 - Power and Environment)
Note
The outlet names on this newly created
PDU will by default be “Outlet 1” “Outlet 2”. When you connect an
particular Managed Device (that draws power from the outlet) they the outlet will then take up the name of the
powered Managed Device
To add a new serially connected Managed Device:
Configure the serial port using the
Serial&Network: Serial Port
menu (refer
Section 4.1 -Configure Serial Port )
Select
Serial&Network: Managed Devices
and click
Add Device
Enter a
Device Name
and
Description
for the Managed Device
Click
Add Connection
and select
Serial
and the
Port
that connects to the Managed Device
To add a UPS/RPC power connection or network connection
or another serial connection click
Add Connection
Click
Apply
Содержание ACM5000
Страница 3: ......
Страница 10: ...Table of Contents 10 Console Server RIM Gateway User Manual...
Страница 11: ......
Страница 94: ...Chapter 5 Firewall Failover and Out of Band 94 Console Server RIM Gateway User Manual...
Страница 119: ......
Страница 149: ......
Страница 191: ......
Страница 205: ......
Страница 225: ......
Страница 303: ......
Страница 313: ......
Страница 323: ......