The unit also has an M20 conduit entry on the side. A 20mm to 1/2“ adaptor can be fitted if imperial sized conduit is
being used. The enclosure has an o-ringed plug installed in the conduit entry as shipped from the factory. If the
conduit connection is used, the installer must make sure that water cannot enter the enclosure from the conduit.
The two wire grommets are designed for a single wire/cable each, which is 3.5-5mm in diameter (0.138 – 0.197”).
This range is intended to accommodate most Ethernet and alarm signal cables used in the industry.
Puncture the diaphragm inside of the grommet by inserting a wire or by using a sharp tool and gently pull the cable
back to secure and seal.
4.3.3
Installation Steps
The ceiling base is attached to a wall or ceiling surface via the four holes located outside the trim ring seal joint.
These holes are located on the two “ears” of the enclosure, are open to the back, and are not threaded. These
holes will pass typical #10 hardware and have 25mm (1”) of internal boss to pass through The fixing hardware used
should be appropriate for the surface material, and should collectively support at least four times the weight of the
camera and assembled enclosure. If the installation is subject to vandalism, additional consideration needs to be
made when selecting fixing hardware and mounting strategies. The enclosure is designed to cover a hole or box in
the mounting surface through which the wires are pulled.
Do not put more than one wire through a
cable entry grommet as it will not seal properly.
This may invalidate the warranty.
Do not drill holes through the enclosure.
This will defeat the IP66 rating and it will not seal properly.