4- programming software (INDEXWORK)
Quick reference NS600
OMRON EUROPE MAC centre
QUICK REFERENCE NS600.DOC
Pag. 24
4.3.7.- JOG or speed table
In this table up to 16 jog speeds are defined, as it has been connected at the beginning of this guide this speeds are
accessible in mode 1 using the digital inputs JSPD3,JSPD2,JSPD1,JSPD0 and also the direction by JOGP and JOGN.
4.3.8.- ZONE.
When the actual position is between the lower and upper limit of the zone, the outputs defined in this table will be
activated but in the actual positioning the POUT field should be Zone, in other case the zones outputs will not be
activated.
If upper limit = lower limit, the zone is inactive
In case of overlap zones, only the low number zone will be active, zone 0 has priority over all the other zones.