4.3 Subcommands
93
4.3.7 Release Latch Mode (LTMOD_OFF: 29H)
4.3.8 Status Monitoring (SMON: 30H)
Byte
LTMOD_OFF
Description
Command
Response
17
29H
29H
Processing
classifications
Control com-
mand group
Processing time
Within commu-
nications cycle
18
-
SUBSTATUS
• Releases the modal latch mode.
This command has the same function as the main command
LTMOD_OFF.
19
SEL_MON
3/4
SEL_MON
3/4
20
-
MONITOR3
21
22
23
24
MONITOR4
25
26
27
28
-
-
29
Byte
SMON
Description
Command
Response
17
30H
30H
Processing
classifications
Data communi-
cations com-
mand group
Processing time
Within commu-
nications cycle
18
-
SUBSTATUS
• Reads the monitoring information specified in SEL_MON3/4.
This command has the same function as the main command SMON.
19
SEL_MON
3/4
SEL_MON
3/4
20
-
MONITOR3
21
22
23
24
MONITOR4
25
26
27
28
-
-
29
TOEP_C710806_03A_1_0.book Seite 93 Montag, 2. Juli 2007 3:55 15