4.4 Combination of MECHATROLINK-
II
Main Commands and Subcommands
94
4.4
Combination of MECHATROLINK-
II
Main Commands and
Subcommands
MECHATROLINK-
II
subcommands can be used by combining as listed below.
Note:
9
: Can be combined.
×
: Cannot be combined.
If a command with a subcommand that cannot be combined is received, the warning A.95d
or A.95E (see
8.3.2 Warning Display and Troubleshooting
for details.) will occur, and the
command will be ignored.
The servo is not OFF and the servomotor is not stopped if a command with a subcommand
that cannot be combined is received during operation.
Code
Main
Command
Subcommand
NOP
PRM_
RD
PRM_
WR
ALM_
RD
PPRM_
WR
LTMOD
_ON
LTMOD
_OFF
SMON
00
NOP
9
9
9
9
9
9
9
9
01
PRM_RD
9
×
×
×
×
×
×
9
02
PRM_WR
9
×
×
×
×
×
×
9
03
ID_RD
9
9
9
9
9
9
9
9
04
CONFIG
9
×
×
×
×
×
×
9
05
ALM_RD
9
×
×
×
×
×
×
9
06
ALM_CLR
9
×
×
×
×
×
×
9
0D
SYNC_SET
9
×
×
×
×
×
×
9
0E
CONNECT
9
×
×
×
×
×
×
9
0F
DISCON-
NECT
1C
PPRM_WR
9
×
×
×
×
×
×
9
20
POS_SET
9
×
×
×
×
×
×
9
21
BRK_ON
9
×
×
×
×
×
×
9
22
BRK_OFF
9
×
×
×
×
×
×
9
23
SENS_ON
9
×
×
×
×
×
×
9
24
SENS_OFF
9
×
×
×
×
×
×
9
25
HOLD
9
9
9
9
9
9
9
9
28
LTMOD_ON
9
×
×
×
×
×
×
9
29
LTMOD_
OFF
9
×
×
×
×
×
×
9
30
SMON
9
9
9
9
9
9
9
9
31
SV_ON
9
9
9
9
9
9
9
9
32
SV_OFF
9
9
9
9
9
9
9
9
34
INTERPO-
LATE
9
9
9
9
9
9
9
9
35
POSING
9
9
9
9
9
9
9
9
36
FEED
9
9
9
9
9
9
9
9
38
LATCH
9
9
9
9
9
×
×
9
39
EX_POSING
9
9
9
9
9
×
×
9
3A
ZRET
9
9
9
9
9
×
×
9
IMPORTANT
TOEP_C710806_03A_1_0.book Seite 94 Montag, 2. Juli 2007 3:55 15