7.2 List of Parameters
129
7.2
List of Parameters
<Conditions to Validate Settings>
A: Immediately validated after setting or changing
B: Validated when DEN = 1
(Do not change when DEN = 0. If any change is made when DEN = 0, safe operation cannot be
secured.)
C: Validated when the power supply is turned OFF and then ON again, or by sending CONFIG com-
mand.
Param-
eter
No.
Name
Data
Size
Min.
Set Value
Max.
Set Value
Units
Factory Set-
ting
Valida-
tion
Refer-
ence
Page
Pn000
Function
Selection
Basic Switch 0
2
—
—
—
0010
C
119
Pn00A
Filter Setting*
2
0000H
000FH
—
0000H
A
118
Pn20E
Electronic
Gear Ratio
(Numerator)
4
1
1073741824
—
1
C
122
Pn210
Electronic
Gear Ratio
(Denominator)
4
1
1073741824
—
1
C
122
Pn304
JOG Speed
2
0
10000
min
-1
500
A
—
* The setting method is the same as for FIL rotary switch. Refer to
6.1 Filter Setting
.
n.
4th
digit
3rd
digit
2nd
digit
1st
digit
Reserved
Reserved
Reserved
0
1
2 and 3
Sets CCW as forward direction.
Sets CW as forward direction.
(Reverse Rotation Mode).
Reserved (Do not change)
Rotation Direction Selection
1
Do not change.
0
Do not change.
0
Do not change.
TOEP_C710806_03A_1_0.book Seite 129 Montag, 2. Juli 2007 3:55 15