71
Setting the Carrier Frequency
Chapter 6-1
The Inverter cannot maintain rated output current with the carrier frequency
set to a value higher than the default one.
The following table shows the default value and a decrease in the output
current of each Inverter model.
Be sure to use the Inverter so that there will be no decrease in rated output
current.
Set Values
• Normally set n75 to 0.
• When the output frequency is 5 Hz or higher and the output current rate is
110% or less, the carrier frequency will be automatically reduced to 2.5
kHz with n75 set to 1. If the load is heavy at low speed, the Inverter will
withstand higher overcurrent by suppressing the heat radiation of the
Inverter caused by the carrier frequency.
• This function is enabled with 2, 3, or 4 set in n46 for carrier frequency.
Voltage Model
CIMR-J7AZ-
Default setting
Rated output
current (A)
Set to 3 Reduced
rated output
current (A)
Set to 4 Reduced
rated output
current (A)
3-phase
200 V
20P1
4 (10 kHz)
0.8
Q
Q
20P2
4 (10 kHz)
1.6
Q
Q
20P4
4 (10 kHz)
3.0
Q
Q
20P7
4 (10 kHz)
5.0
Q
Q
21P5
3 (7.5 kHz)
8.0
Q
7.0
22P2
3 (7.5 kHz)
11.0
Q
10.0
24P0
3 (7.5 kHz)
17.5
Q
16.5
Single-phase
200 V
B0P1
4 (10 kHz)
0.8
Q
Q
B0P2
4 (10 kHz)
1.6
Q
Q
B0P4
4 (10 kHz)
3.0
Q
Q
B0P7
4 (10 kHz)
5.0
Q
Q
B1P5
3 (7.5 kHz)
8.0
Q
7.0
3-phase 400 V
40P2
3 (7.5 kHz)
1.2
Q
1.0
40P4
3 (7.5 kHz)
1.8
Q
1.6
40P7
3 (7.5 kHz)
3.4
Q
3.0
41P5
3 (7.5 kHz)
4.8
Q
4.0
42P2
3 (7.5 kHz)
5.5
Q
4.8
44P0
3 (7.5 kHz)
8.6
Q
7.6
n75
Low Carrier Frequency at Low Speed
Changes during
operation
No
Setting
range
0, 1
Unit of
setting
1
Default setting
0
Value Description
0
Low carrier frequency at low speed disabled.
1
Low carrier frequency at low speed enabled.
Содержание J7 series
Страница 12: ...XII...
Страница 15: ...1 CHAPTER 1 Overview 1 1 Function 2 1 2 Nomenclature 3...
Страница 47: ...33 CHAPTER 3 Preparing for Operation and Monitoring 3 1 Nomenclature 34 3 2 Outline of Operation 35...
Страница 54: ...40 Outline of Operation Chapter 3 2...
Страница 102: ...88 Other Functions Chapter 6 7...
Страница 158: ...144 Option Specifications Chapter 9 3...
Страница 159: ...145 CHAPTER 10 List of Parameters List of Parameters 146...
Страница 172: ...158 List of Parameters Chapter 10...
Страница 173: ...159 CHAPTER 11 Using the Inverter for a Motor Using the Inverter for a Motor 160...