86
Other Functions
Chapter 6-7
Set Values
The following ON/OFF combinations of UP and DOWN commands are
possible.
With the UP/DOWN function used, the output frequency has the following
restrictions for upper and lower limits.
Upper limit: The maximum frequency in n09 or the frequency reference
upper limit in n30, whichever is smaller.
Lower limit: The minimum output frequency in n14 or frequency reference
lower limit in n31, whichever is smaller.
Value Description
0
The frequency on hold is not retrained.
1
The frequency on hold for 5 s or more is retailed.
Operation of UP/DOWN Function
RUN command
(Forward rotation)
UP command
(S4)
DOWN command
(S5)
Output frequency
Upper limit
Lower limit
Status
Frequency
detection
Time
Time
Time
Time
Time
Note
Status U: UP (acceleration)
D:
DOWN
(deceleration)
H:
Hold
U1: Frequency acceleration restricted by upper limit.
D1: Frequency deceleration restricted by lower limit.
Command Acceleration
Deceleration
Hold Hold
S4 (UP command)
ON OFF OFF ON
S5 (DOWN command)
OFF
ON
OFF
ON
Содержание J7 series
Страница 12: ...XII...
Страница 15: ...1 CHAPTER 1 Overview 1 1 Function 2 1 2 Nomenclature 3...
Страница 47: ...33 CHAPTER 3 Preparing for Operation and Monitoring 3 1 Nomenclature 34 3 2 Outline of Operation 35...
Страница 54: ...40 Outline of Operation Chapter 3 2...
Страница 102: ...88 Other Functions Chapter 6 7...
Страница 158: ...144 Option Specifications Chapter 9 3...
Страница 159: ...145 CHAPTER 10 List of Parameters List of Parameters 146...
Страница 172: ...158 List of Parameters Chapter 10...
Страница 173: ...159 CHAPTER 11 Using the Inverter for a Motor Using the Inverter for a Motor 160...