Selecting Indicators
Whenever the Mode Key is pressed, an indicator is lit in sequence beginning
with the FREF indicator. The data display indicates the item corresponding to
the indicator selected.
The FOUT or IOUT indicator will be lit by turning the Inverter on again if the
Inverter is turned off while the FOUT or IOUT indicator is lit. The FREF
indicator will be lit by turning the Inverter on again if the Inverter is turned off
while an indicator other than the FOUR or IOUT indicator is lit.
Power ON
FREF (Frequency Reference)
Monitors and sets the frequency reference.
FOUT (Output Frequency)
Monitors the output frequency.
Note
This indicator will be lit by turning the Inverter on again if the
Inverter is turned off while this indicator is lit.
IOUT (Output Current)
Monitors the output current.
Note
This indicator will be lit by turning the Inverter on again if the
Inverter is turned off while this indicator is lit.
MNTR (Multi-function Monitor)
Monitors the values set in U01 through U10.
F/R (Forward/Reverse Rotation)
Selects the direction of rotation.
LO/RE (Local/Remote)
Selects the operation of the Inverter through the Digital Operator or
according to the parameters.
PRGM (Parameter Setting)
Monitors or sets the values in n01 through n79.
The FREF indicator is lit again.
Содержание J7 series
Страница 12: ...XII...
Страница 15: ...1 CHAPTER 1 Overview 1 1 Function 2 1 2 Nomenclature 3...
Страница 47: ...33 CHAPTER 3 Preparing for Operation and Monitoring 3 1 Nomenclature 34 3 2 Outline of Operation 35...
Страница 54: ...40 Outline of Operation Chapter 3 2...
Страница 102: ...88 Other Functions Chapter 6 7...
Страница 158: ...144 Option Specifications Chapter 9 3...
Страница 159: ...145 CHAPTER 10 List of Parameters List of Parameters 146...
Страница 172: ...158 List of Parameters Chapter 10...
Страница 173: ...159 CHAPTER 11 Using the Inverter for a Motor Using the Inverter for a Motor 160...