141
Specifications of Accessories
Chapter 9-2
9-2-10 AC Reactor
The AC Reactor suppresses harmonic current generated from the Inverter
and improves the power factor of the Inverter. Connect the AC Reactor to the
Inverter if the capacity of the power supply is much larger than that of the
Inverter. Select the AC Reactor model from the following table according to
the motor capacity.
Connection Example
Applicable Range
Applicable Models and Dimensions
200-V Class
400-V Class
MCCB AC Reactor
Motor
Power supply
capacity (kVA)
AC Reactor required
for smooth operation
under present power
supply conditions
AC Reactor
not required
Inverter capacity (kVA)
Max. applicable motor capacity
(kW)
Current (A)
Inductance (mH)
0.1 to 0.2
2
7.0
0.4 2.5
4.2
0.75 5
2.1
1.5 10
1.1
2.2 15
0.71
4.0
20 0.53
Max. applicable
motor capacity (kW)
Current (A)
Inductance (mH)
0.2 to 0.4
1.3
18.0
0.75 2.5
8.4
1.5 5
4.2
2.2 7.5
3.6
4.0
10 2.2
Содержание J7 series
Страница 12: ...XII...
Страница 15: ...1 CHAPTER 1 Overview 1 1 Function 2 1 2 Nomenclature 3...
Страница 47: ...33 CHAPTER 3 Preparing for Operation and Monitoring 3 1 Nomenclature 34 3 2 Outline of Operation 35...
Страница 54: ...40 Outline of Operation Chapter 3 2...
Страница 102: ...88 Other Functions Chapter 6 7...
Страница 158: ...144 Option Specifications Chapter 9 3...
Страница 159: ...145 CHAPTER 10 List of Parameters List of Parameters 146...
Страница 172: ...158 List of Parameters Chapter 10...
Страница 173: ...159 CHAPTER 11 Using the Inverter for a Motor Using the Inverter for a Motor 160...