82
Ch
apt
e
r
5
Wir
ing Examples
F3SG-4RA-25-02TS
User’s Manual
Input/Output Circuit and Applications
5-2. Wiring Examples
Examples of a motor control system using the F3SG-R are shown below. This chapter shows examples
equivalent to up to PLe, Category 4 (ISO13849-1).
5-2-1. EDM used and External Test in 24V Active not used
The following is the example of External Device Monitoring used and External Test in 24 V Active (not
used).
[Settings]
[Wiring Example]
Functional earth connection is unnecessary when you use the F3SG-R in a general industrial environment where noise
control or stable power supply is considered. However, when you use the F3SG-R in an environment where there may
be excessive noise from surroundings or stable power supply may be interfered, it is recommended the F3SG-R be
connected to functional earth.
The wiring examples in later pages do not indicate functional earth. To use functional earth, wire an earth cable
according to the example above. Refer to
4-5-4. Functional Earth Connection
for more information.
Function
Receiver
EDM
Emitter
External Test: 24 V Active (End Cap: Black) (factory default setting)
Unblocked
Blocked
Beam state
OSSD
KM1, KM2: Safety relay with forcibly guided contacts (G7SA)
M: Motor
+24 VDC (Brown)
Not used (Yellow) *3
TEST (Black) *1
Not used (White) *3
Not used (Red) *3
Not used (Pink)
Not used (Gray)
0 VDC (Blue)
OSSD 1 (Black)
OSSD 2 (White)
+24 VDC (Brown)
0 VDC (Blue)
AUX (Yellow)
PC COM (-) (Pink)
PC COM (+) (Gray)
EDM (Red) *2
Functional Earth
F39-JD
□□
A-L *4
F39-JD
□□
A-D *4
KM1
KM2
M
KM1 KM2
KM1
KM2
Power Supply
+24 VDC
0 VDC
Receiver
Emitter
*1. Connect the line to 24 V via a test switch (N.O. contact) if External Test is
used.
*2. Connect a lockout reset switch (N.C. contact) to this line in series with the
KM1 and KM2 if Lockout Reset is used.
*3. The F39-JD
□
RA-L Single-Ended Cable for Emitter (Oil-Resistant Cable)
does not have the red, white and yellow wires.
*4. For the F39-JD
□
A-
□
Single-Ended Cable, connect the shield line to 0 V.
Содержание F3SG-R Series
Страница 19: ...xvii F3SG 4RA 25 02TS User s Manual Introduction E 7 4 Revision History 107...
Страница 20: ...xviii Introduction F3SG 4RA 25 02TS User s Manual...
Страница 52: ...32 Chapter 3 End Cap F3SG 4RA 25 02TS User s Manual Setting with Rotary Switch and End Cap...
Страница 106: ...86 Chapter 5 Connectable Safety Control Units F3SG 4RA 25 02TS User s Manual Input Output Circuit and Applications...
Страница 112: ...92 Chapter 6 Maintenance Checklists F3SG 4RA 25 02TS User s Manual Checklists...