14
Chapter
2
Opera
ting St
ate
s
F3SG-4RA-25-02TS
User’s Manual
System Operation and Functions
2-1. Operating States
The operating condition of a F3SG-R system is described in terms of states. The following operating states
exist for a F3SG-R system.
2-1-1. Machine Run State
The two receiver safety outputs are in the ON state, the green ON/OFF indicator is illuminated. The
protected machine is allowed to operate. Pressing and releasing the reset switch has no effect.
2-1-2. Machine Stop State
The two receiver safety outputs are in the OFF state, the red ON/OFF indicator is illuminated. The
protected machine is not allowed to operate.
2-1-3. Lockout State
The two receiver safety outputs are in the OFF state, the red Lockout indicator is blinking, and another
indicator is blinking showing an error. The Lockout state does not allow the protected machine to
operate. The F3SG-R system will remain in the Lockout state until the cause of the error is corrected,
regardless of power cycling or an external reset switch press and release.
Содержание F3SG-R Series
Страница 19: ...xvii F3SG 4RA 25 02TS User s Manual Introduction E 7 4 Revision History 107...
Страница 20: ...xviii Introduction F3SG 4RA 25 02TS User s Manual...
Страница 52: ...32 Chapter 3 End Cap F3SG 4RA 25 02TS User s Manual Setting with Rotary Switch and End Cap...
Страница 106: ...86 Chapter 5 Connectable Safety Control Units F3SG 4RA 25 02TS User s Manual Input Output Circuit and Applications...
Страница 112: ...92 Chapter 6 Maintenance Checklists F3SG 4RA 25 02TS User s Manual Checklists...