8
Chapter
1
Ra
tings
/Sp
ecif
ic
a
tion
s
F3SG-4RA-25-02TS
User’s Manual
Overview and Specifications
1-5. Ratings
/
Specifications
The
□□□□
in the model names indicate the protective heights in millimeters.
F3SG-4RA
-25-02TS
Performance
Object Resolution
(Detection Capability)
Opaque objects, 25-mm dia.
Beam Gap
20 mm
Number of Beams
12 to 96
Lens Size
6.0 × 5.0 (W × H) mm
Protective Height
240 to 1920 mm
Operating Range
0.3 to 17.0 m
Response Time
ON to OFF Normal mode: 8 to 13 ms *
OFF to ON Normal mode: 40 to 90ms (synchronized), 140 to 190ms (not synchronized) *
*. Response time when used in one segment system or in cascaded connection.
Effective Aperture Angle
(EAA) (IEC 61496-2)
±2.5° max., emitter and receiver at operating range of 3 m or greater
Light Source
Infrared LEDs, Wavelength: 870 nm
Startup Waiting Time
2 s max.
Electrical
Power Supply Voltage (Vs)
SELV/PELV 24 VDC±20% (ripple p-p 10% max.)
Current Consumption
Safety Outputs (OSSD)
Two PNP transistor outputs
Load current of 300 mA max., Residual voltage of 2 V max. (except for voltage drop due to cable
extension), Capacitive load of 1
F max., Inductive load of 2.2 H max. *1
Leakage current of 1 mA max. *2
*1. The load inductance is the maximum value when the safety output frequently repeats ON and OFF.
When you use the safety output at 4 Hz or less, the usable load inductance becomes larger.
*2. These values must be taken into consideration when connecting elements including a capacitive
load such as a capacitor.
Auxiliary Output
One PNP transistor output
Load current of 100 mA max., Residual voltage of 2 V max .
Output Operation
Mode
Safety
Output
Light-ON (Safety output is enabled when the receiver receives an emitting signal.)
Auxiliary
Output
Reverse output of safety output
Input Voltage
External
device
monitoring
input
(Lockout
reset input)
ON voltage: Vs-3 V to Vs (short circuit current: approx. 6.5 mA) *
OFF voltage: 0 V to 1/2 Vs, or open (short circuit current: approx. 8.0 mA) *
Test input
24 V Active setting:
ON voltage: 9 V to Vs (short circuit current: approx. 2.5 mA) *
OFF voltage: 0 to 1.5 V or open (short circuit current: approx. 2.0 mA)
0 V Active setting:
ON voltage: 0 to 3 V (short circuit current: approx. 2.0 mA)
OFF voltage: 9 V to Vs or open (short circuit current: approx. 2.5 mA) *
* The Vs indicates a supply voltage value in your environment.
Overvoltage Category
(IEC 60664-1)
II
Indicators
Protective Circuit
Output short protection, Power supply reverse polarity protection
Insulation Resistance
20 M
or higher (500 VDC megger)
Dielectric Strength
1,000 VAC, 50/60 Hz (1 min)
Содержание F3SG-R Series
Страница 19: ...xvii F3SG 4RA 25 02TS User s Manual Introduction E 7 4 Revision History 107...
Страница 20: ...xviii Introduction F3SG 4RA 25 02TS User s Manual...
Страница 52: ...32 Chapter 3 End Cap F3SG 4RA 25 02TS User s Manual Setting with Rotary Switch and End Cap...
Страница 106: ...86 Chapter 5 Connectable Safety Control Units F3SG 4RA 25 02TS User s Manual Input Output Circuit and Applications...
Страница 112: ...92 Chapter 6 Maintenance Checklists F3SG 4RA 25 02TS User s Manual Checklists...