![background image](http://html1.mh-extra.com/html/omron/f3sg-r-series/f3sg-r-series_user-manual_744006063.webp)
43
F3SG-4RA-25-02TS
User’s Manual
Chapter
4
Cas
c
ade Conne
ct
ion
Wiring/Installation
E
Properly connect an emitter to another emitter, and a receiver to another receiver, as shown below.
If caps and Cascading Cables are not connected properly, the F3SG-R enters lockout (when power is turned ON).
Do not series-connect an emitter and receiver.
They will enter lockout state.
Do not face different models of emitters and
receivers toward each other. They will enter
lockout state or will be unable to detect objects.
Secondary
sensor 1
(Emitter)
Secondary
sensor 1
(Emitter)
Secondary
sensor 1
(Emitter)
Secondary
sensor 1
(Receiver)
Secondary
sensor 1
(Receiver)
Secondary
sensor 1
(Receiver)
Primary
sensor
(Emitter)
Primary
sensor
(Emitter)
Primary
sensor
(Emitter)
Primary
sensor
(Receiver)
Primary
sensor
(Receiver)
Primary
sensor
(Receiver)