Before mounting
When it is required to configure the following functions, do so before installing the F3SG-R in your site,
according to the respective procedures.
• Scan Code Selection:
• External Test Input Selection:
4-4-3-1. Mounting with Free-Location Brackets (F39-LGRA)
1.
Securely tighten the screws to fix the Free-Location Bracket to the mounting position of the wall
surface. (Fig. 1)
Screws to mount the brackets to the wall are not included.
2.
Fully loosen the Mounting Screws (hexagon socket head cap screw (M4×22)). Fit the backside of the
F3SG-R housing to the Brackets (1) and (2) so that the groove of the backside of the housing receives
the hooks of the Brackets (1) and (2). (Fig. 2)
The width across flat of the hexagon socket of the Mountng Screws is S=3.
<Backside mounting>
<Side mounting>
Fig. 1
M5/M6
M5/M6
Fig. 2
Mounting Screw
(hexagon socket head
cap screw (M4×22))
Loosen this
Bracket (1)
Bracket (2)
Fit the backside of the housing
to the hooks
Содержание F3SG-R Series
Страница 19: ...xvii F3SG 4RA 25 02TS User s Manual Introduction E 7 4 Revision History 107...
Страница 20: ...xviii Introduction F3SG 4RA 25 02TS User s Manual...
Страница 52: ...32 Chapter 3 End Cap F3SG 4RA 25 02TS User s Manual Setting with Rotary Switch and End Cap...
Страница 106: ...86 Chapter 5 Connectable Safety Control Units F3SG 4RA 25 02TS User s Manual Input Output Circuit and Applications...
Страница 112: ...92 Chapter 6 Maintenance Checklists F3SG 4RA 25 02TS User s Manual Checklists...