69
F3SG-4RA-25-02TS
User’s Manual
Chapter
4
Wiring
Wiring/Installation
E
4-5. Wiring
4-5-1. Wiring Precautions
Double or reinforced insulation from hazardous voltage must be applied to all input and
output lines. Failure to do so may result in electric shock.
Connect the load between the output and 0 V line.
Connecting between the output and a different power supply line from the above line will
result in dangerous condition because the operation mode of safety output is reversed to
"Dark-ON".
Do not 24 VDC line. Otherwise, a ground fault may turn the safety output ON,
resulting in a failure of stopping the machine.
Configure the system by using the optimal number of safety outputs that satisfy the
requirements of the necessary safety category.
Do not connect each line of F3SG-R to a DC power supply higher than 24 VDC+20%.
Also, do not connect it to an AC power supply.
Failure to do so may result in electric shock.
Make sure to perform wiring while the power supply is OFF.
+24 VDC
0 VDC
+24 VDC
0 VDC
Brown
Black, White
Blue
Receiver
F3SG
Brown
Black, White
Blue
Load
Load
F3SG
Receiver
Содержание F3SG-R Series
Страница 19: ...xvii F3SG 4RA 25 02TS User s Manual Introduction E 7 4 Revision History 107...
Страница 20: ...xviii Introduction F3SG 4RA 25 02TS User s Manual...
Страница 52: ...32 Chapter 3 End Cap F3SG 4RA 25 02TS User s Manual Setting with Rotary Switch and End Cap...
Страница 106: ...86 Chapter 5 Connectable Safety Control Units F3SG 4RA 25 02TS User s Manual Input Output Circuit and Applications...
Страница 112: ...92 Chapter 6 Maintenance Checklists F3SG 4RA 25 02TS User s Manual Checklists...