Chapter 4 Command Description
4-29 Reset Software (9FHex)
3D TOF Sensor Module B5L User's Manual (No. E596)
4-29 Reset Software (9FHex)
Resets this product.
Command (from host to this product)
Synchroni
zation
code
Comman
d No.
Data length
FEHex
9FHex
00Hex
00Hex
Response (from this product to host)
Synchroni
zation
code
Response
code
Data length
Data
FEHex
Normal
end: 00Hex
00Hex
00Hex
00Hex
00Hex
Error:
FFHex to
F0Hex
00Hex
00Hex
00Hex
00Hex
・
Data details
Stops the distance measurement and goes back to the status after power ON
.
The following parameter settings are retained
.
- Result acquisition format (output information, coordinate system)
- Operation mode (normal/high-speed)
- Exposure time/frame rate
- T3D rotation angle
- LED emission frequency ID
- MIN_AMP (for all range)
- MIN_AMP (for close distance)
- Enabling/disabling operation check LED
- Responder speed setting (transmission size/interval)
- ENR threshold
If this command is executed, the USB connection is released.
After executing this command, there is a waiting time of about 10 seconds before the next
command can be accepted.
66