Chapter 2 Installation & Wiring
2-2 Wiring
3D TOF Sensor Module B5L User's Manual (No. E596)
2-2 Wiring
External power supply
This product by itself does not conform to fireproof enclosure requirements
.
Use a power supply that complies with IEC 62368-1 LPS (Limited Power Supply
Requirements) for incorporation
.
Precautions on connection configuration
Shown below is the connection configuration
.
Note 1: To obtain the limit values for radiation interference level (e.g. CISPR22 Class A), check and take
measures as the product in which this product is incorporated.
Noise countermeasures for the connection lines can be expected to reduce the level of radiated
noise.
Please evaluate the cable and GND connection (e.g. FG connection) before making your decision.
Note 2: Pay attention to creepage distance and other factors to prevent static electricity from being
applied to any part of the enclosure other than the emitter and receiver surfaces.
Separate the mounting holes of this product from the FG.
Power supply connection
Wire the 24VDC power supply to the power connector shown below.
Power connector
Housing and contact, J.S.T. Mfg. Co., Ltd.
To 24VDC
USB cable
Power cable
Customer's system
This product
Em
itte
r/rec
ei
ver
Mi
cro
U
SB
25