![Omicron Lab CT Analyzer Скачать руководство пользователя страница 13](http://html2.mh-extra.com/html/omicron-lab/ct-analyzer/ct-analyzer_user-manual_3973450013.webp)
11
Introduction
1
Introduction
1.1
Designated Use
The
CT Analyzer
is intended to perform automatic testing and calibration of low
leakage flux current transformers (i.e., CTs with non-gapped cores) in
laboratories as well as on-site in utilities. Testing of CTs with gapped cores is
also possible with restricted accuracy. The following tests can be performed
using the
CT Analyzer
:
• Burden measurement
• Residual magnetism measurement of CTs
• CT winding resistance measurement
• CT excitation characteristic measurement according to IEC 61869-2,
IEC 60044-1, IEC 60044-6 (TPS, TPX, TPY, TPZ) and IEEE C57.13.
• CT ratio measurement with consideration of a connected burden
• CT phase and polarity measurement
• Determination of accuracy limiting factor, instrument security factor,
secondary time constant, symmetrical short-circuit current factor, transient
dimensioning factor, remanence factor, knee point voltage/current, class,
saturated inductance and non-saturated inductance.
Using the
Quick Test
feature it is also possible to use the
CT Analyzer
as a
versatile multimeter with included power source, e.g. for:
• Quick and easy resistance measurement, e.g. for wiring checks on the
secondary side of CTs.
• Quick voltage ratio checks for VTs.
• Measurement of burden values, e.g. to determine the new burden value after
changes of the relay equipment. This allows the re-calculation of the CT test
results for the new burden value by the
CT Analyzer
and thus makes it
unnecessary to run an additional CT test in order to determine the behavior
of the CT with the new burden.
• Quick wiring checks using the
CPOL
polarity checker from OMICRON. Using
the
CPOL
in combination with the specific test signal provided by the
CT Analyzer
’s
Quick Test
feature you can check a series of test points (e.g.,
the burden wiring) for correct polarity.
The
CT Analyzer
is intended exclusively for the applications described above.
Any other use is deemed not to be according to the regulations. The
manufacturer and the distributor are not liable for damage resulting from
improper usage. The user alone assumes all responsibility and risk.
Содержание CT Analyzer
Страница 1: ...CT Analyzer CT SB2 User Manual...
Страница 3: ...CT Analyzer User Manual...
Страница 4: ...CT Analyzer User Manual 2 Manual Version CTAnalyzerUM AE 3...
Страница 39: ...37 Setup and Connection Figure 2 15 Measurement setup for delta compensation Ratio 1 L2 L3 L1...
Страница 50: ...CT Analyzer User Manual 48...
Страница 60: ...CT Analyzer User Manual 58...
Страница 80: ...CT Analyzer User Manual 78...
Страница 162: ...CT Analyzer User Manual 160...
Страница 172: ...CT Analyzer User Manual 170...
Страница 188: ...CT Analyzer User Manual 186...
Страница 194: ...CT Analyzer User Manual 192...
Страница 195: ...CT SB2 User Manual...
Страница 196: ...CT SB2 User Manual 2 Manual Version CTSB2 AE 3...
Страница 204: ...CT SB2 User Manual 10...
Страница 206: ...CT SB2 User Manual 12...
Страница 211: ...17 Hardware 1 x Cable bag Bag for cables and accessories Accessories Description...
Страница 212: ...CT SB2 User Manual 18...
Страница 226: ...CT SB2 User Manual 32...
Страница 242: ...CT SB2 User Manual 48...
Страница 248: ...CT SB2 User Manual 54...
Страница 250: ...CT SB2 User Manual 56...
Страница 252: ...CT SB2 User Manual 58...