Page - 26
Feature #3 Automatic Rearming
(Factory Default Setting Off)
“Automatic Rearming”, described on page 10, prevents the system from becoming accidentally
disarmed.
Feature #2 Last Door Arming
(Factory Default Setting Off)
“Last Door Arming” has the system automatically arm itself every time you exit the vehicle (the
complete operation is described on page 7). This feature turns that operation on or off.
Feature #4 Automatic Starter Interrupt
(Factory Default Setting Off)
Turning on this feature will cause the Starter Interrupt output to automatically engage 90 seconds
after the ignition switch is turned "off", and also 90 seconds after disarming the system. This auto-
matic engagement will occur even if the security system is in a disarmed state, but not if it is in Valet
Mode. Once the Starter Interrupt output is activated, the system must be armed, then disarmed with
the transmitter, or placed into the Valet Mode by pressing and holding the Valet Switch for 2 seconds
to disengage it. There are no Status Light indications with this automatic form of Starter Interrupt.
Feature #5 Doors Lock With Last Door Arming
(Factory Default Setting Off)
This feature adds the automatic locking of the doors to the Last Door Arming operation. If this feature
is added to feature #4, when the system becomes armed 30 seconds after closing the last door the doors
will also lock . This feature will operate only if feature #2 is turned on.
Feature #6 Doors Lock With Automatic Rearming
(Factory Default Setting Off)
This feature adds the automatic locking of the doors to the Automatic Rearming operation. If this
feature is added to feature #3, when the system rearms itself 90 seconds after being disarmed the doors
will also lock. This feature will operate only if feature #3 is turned on.