Thanks for buying the photoelectric and temperature smoke alarm. Read all 

instructions before installing the smoke alarm, so it will protect your home in 
the best possible way.

• If you are installing the smoke alarm for some other person, leave these 
instructions or a copy of them with him/her.

• The photoelectric and temperature smoke alarm is also suitable for use 

in a travel vehicle, such as camper vans, caravans, and boats.
• Allow interconnect 30 detectors.

1. POSITIONING THE SMOKE ALARM

• Place at least one smoke alarm per 60 m 2 on each floor.

• Place a smoke alarm in each corridor and bedroom.

• The smoke alarm is to be placed on the calling in such a way that it is in 

the middle of the room.

Alarm mode: 

When the smoke alarm detects smoke, it goes into an alarm 

mode  in  which  the  smoke  alarm  sounds  with  a  frequency  of  3  times 
continuously and the red light flash.

Error mode: 

When the detectors detect any anomaly, the smoke alarm beeps

at intervals of 50 seconds.

Low battery: 

When the battery it’s running out, the smoke alarm beeps and

the red light flash at intervals of 50 seconds. You can silence this alarm for 10
hours by press the test button (the detector will remain in operational mode
even if you have silenced the low battery alarm).

Silence mode: 

during alarm mode, pressed the test button for 1 second, the 

smoke alarm is immediately reset out of the alarm condition and the beep is 
silenced for 10 minutes. In silence mode, the red light flashes once every 16 

seconds.

Wireless mode:

Wireless function decription:
Wireless frequency: 868MHz
Wireless distance: >100 meters
Note: Make sure that the batteries have been installed correctly before the 
detectors are put into operation. For the correct operation of the  
detector it will be necessary to acquire the MDAHWF module from COFEM.

The  detectors are capable of interconnect 30 units among them 
with a distance of 100 meters.
Los detectores  permiten la conexión al módulo MDAHWF que le 
permitirá mediante la conexión a una red wifi y la descarga de una aplicación 
móvil poder conocer el estado de su instalación desde cualquier lugar dónde 

se encuentre.

Follow these steps to interconnect the smoke detectors:

1) Proceed with the start-up of the detectors to be interconnected.
2)  Take  the  first  detector  to  connect  and  press  the  test  button  3  times 
consecutively. You can see how the red light turns on. In this moment the 
detector remain in wifi learning mode. 
If you press the test button or the detector doesn’t receive a wireless in less 
than 10 seconds, it will automatically return to
operational mode.
3) When you have the first detector in wireless learning mode (step 2) take 
the second detector and press the test button 3 times consecutively, you can 
hear a double beep and the red light flash, at which time the two detectors 
will be linked.
The detector in learning mode will leave the light fixed again if you want to 
connect another detector. If you don’t want to interconnect more detectors, 
press the test button to exit learning mode and the detectors will remain in 
operational mode.
4) If one of detectors enters in alarm mode, the alarm will be reproduced 
after a few seconds by all interconnected detectors through a double beep 
and the activation of the red light. When the detector that enters in alarm 
mode is stopped, the interconnected detectors are stopped in a few seconds.

3. MAINTENANCE 

The detector used 2 1,5V AA Alkaline batteries. When the detector enters in 
low battery mode it’s recommended replace them for the correct functioning 
of this device.

Warning: 

Do not paint or modify the smoke alarm!

Waste  handing:  The  smoke  alarm  should  be  disposed  in  accordance  with 
normal waste handing for electronics.

AVOID THESE POSITIONS:
Near a wall or corner:

 Place the smoke alarm at a distance of at least 50 cm 

from a wall or corner.

Moist places: 

Avoid installing smoke alarms near moist or occasionally moist 

places such as immediately close to a shower or kitchen, where steam can 

cause false alarm.

Ventilation  ducts: 

Avoid  installing  a  smoke  alarm  immediately  next  to  a 

ventilation  duct.  The  draft  may  prevent  smoke  from  reaching  the  smoke 
alarm. Smoke alarm can't be installed in the location where the air velocity is 
more than 300 ft/min (1.5 m/sec).

Dead-air spaces: 

Avoid installing a smoke alarm in the angle of a pitched roof. 

Install it at a distance of least 10 cm from the ridge.

Fluorescent  lamps:

  Avoid  installing  a  smoke  alarm  immediately  next  to 

fluorescent lamps, such as halogen lights.

Radiation  heating  source: 

Avoid  installing  a  smoke  alarm  radiant  heat  ing 

source, such as radiant heating in the ceiling can create a hot air boundary 
layer along the ceiling surface, which can seriously restrict the movement of 

smoke and heat to a smoke alarm.

2. OPERATION AND TESTING

Start-up: 

When  you  install  the  batteries  for  the  first  time,  or  make  the 

replacement of them, the led will flash for half a second and the detector 
emit one beep: If once this sequence is finished the detector doesn’t emit any 
sound,  the  detector  will  be  operational  and  the  red  light  flash  every  50 

seconds.  

Test mode: 

Press the test button of the smoke alarm for 1 second until you 

hear 3 beeps, after 1.5 seconds will hear again 3 beeps. This will happen for 3 
cycles,  if  you  keep  pressing  the  test  button,  the  cycle  of  beeps  will  be 
repeated  with  an  increase  volume  and  if  there  are  more  interconnected 
detectors,  they  will  also  enter  in  test  mode.  While  holding  down  the  test 
button the red light will also light up. When you release the test button of the 
detector  (and  the  other  interconnected  detectors)  will  return  to  the 
operational mode.

 

 

Compulsory location

Recommended location

Incorrect  installation  will  decrease  operational 

effectiveness.
Place the smoke alarm on the ceiling and position it least 

50cm from the nearest wall or corner.

Bedroom

Bedroom

Hall

Living room

Kitchen

Cellar