![OLiPower BRE-I-5K Скачать руководство пользователя страница 57](http://html1.mh-extra.com/html/olipower/bre-i-5k/bre-i-5k_user-manual_4507674057.webp)
57
·
Check the warning fault messages in the System Control Panel
message is displayed, record it before doing anything further.
·
Attempt the solution indicated in below table.
7.1
Troubleshooting
Mgr EEPROM Fault
The manager eeprom is fault.
·
Disconnect PV, grid, and battery, then reconnect.
·
Or seek help from us, if not go back to normal state.
Meter Lost Fault
The communication between meter and inverter is interrupted.
·
Check if the communication cable between meter and
inverter is correctly and well connected.
Dsp Lost Fault
SCI communication fault
·
Disconnect solar power PV+, PY- and battery, reconnect
them.
·
Or seek help from us, if cannot go back to normal state.
BMS Volt Fault
Battery voltage sensor error
·
Wait for 5 minutes, check again.
·
Or seek help from us, if not go back to normal state.
BMS Tepr Fault
Battery temperature sensor error
·
Wait for 5 minutes, check again
·
Or seek help from us, if not go back to normal state.
BMSIN_COM Fault
BMS internal communication fault.
·
Disconnect battery, check wiring between inverter and
battery , battery internal wiring then reconnect.
·
Or seek help from us, if not go back to normal state.
BMS Dcov Fault
Battery input over voltage error
·
Wait for 5 minutes. check again.
·
Or seek help from us, if not go back to normal state.
BMS RV Fault
Battery input transposition error
·
Wait for 5 minutes. check again.
·
Or seek help from us, if not go back to normal state.
BMS Relay Fault
The battery relay is fault
·
Disconnect battery, then reconnect.
·
Or seek help from us, if not go back to normal state
BMS Cell Fault
Battery cell error
·
Wait for 5 minutes, check again.
Содержание BRE-I-5K
Страница 1: ...1 User Manual BRE I 5K OLIPOWER ENERGY AUTOMATION TECHNOLOGY...
Страница 28: ...28 1 ADD Interface ADD interface PINS definition...
Страница 33: ...33...
Страница 34: ...34...
Страница 51: ...51 6 3 5 System Switch Press up or down button to turn on or turn off the inverter Press OK to confirm...
Страница 54: ...54 Reactive power setting After user log into the system Remote control Reactive power...
Страница 55: ...55 Volt watt setting After user log into the system Remote control Australia...
Страница 62: ...62...