Step 1
Battery Communication Connection
The communication interface between battery and inverter is CAN with a Rj45
connector, The Pins definition is as below
Pin
1
2
3
4
5
6
7
8
Function
NC
NC
NC
CANH
CANL
NC
NC
NC
Step 2
Battery Power Cable Connection
·
Connect one side of the battery connect wire to the Figure 5-9 Position
shown.
·
Connect the positive side of the battery connect wire to the positive side of
the battery.
·
the negative side of the battery connect wire to the negative side of the
battery.
·
Make sure the positive and negative side of battery are connected.
NOTE:
If the resistance to earth of each conductor of the PV array and battery system
lower than the detection, the inverter will report Earth Fault Alarm.
This inverter complies with IEC 62109-2 clause 13.9 for earth fault alarm
monitoring. If an Earth Fault Alarm occurs, the red light will be on and the ISO
Check fault will be displayed on the LCD screen, and the fault can be found in
the history of the fault.
WARNING!
Make sure you select the correct specification cables for
installation.
Otherwise, the power will make the cable hot or burnt; it could result
in death or serious injury
.
Содержание BRE-I-5K
Страница 1: ...1 User Manual BRE I 5K OLIPOWER ENERGY AUTOMATION TECHNOLOGY...
Страница 28: ...28 1 ADD Interface ADD interface PINS definition...
Страница 33: ...33...
Страница 34: ...34...
Страница 51: ...51 6 3 5 System Switch Press up or down button to turn on or turn off the inverter Press OK to confirm...
Страница 54: ...54 Reactive power setting After user log into the system Remote control Reactive power...
Страница 55: ...55 Volt watt setting After user log into the system Remote control Australia...
Страница 62: ...62...