![OLiPower BRE-I-5K Скачать руководство пользователя страница 16](http://html1.mh-extra.com/html/olipower/bre-i-5k/bre-i-5k_user-manual_4507674016.webp)
16
E
1
Meter
F
12
Expansion tubes & Expansion screws
G
6
M5 Screw
H
2
Earth Terminal
I 1
User Manual & Quick installation guide
J
1
Quality Certificate
K
Open the package and pick the product, check that if there is any distortion or
impaired during the transportation. Meanwhile, check that if the relating
accessories and the materials are here, you can see the accessories list in the
table.
The instruction manual is an integral part of the unit and should therefore be read
and kept carefully.
It is recommended that the packaging should not be removed until the unit is in the
installation site
5.2
Check for transport damage
Check if the N1-HV series inverter has some visible external damage, such as
cracks in the housing or display please contact with your dealer if you find any
damage.
5.3
Installation precaution
The inverter is designed for outdoor installation.
Make sure the installation site does not fall into one of the following conditions:
·
Do not install the inverter in direct sunlight.
·
Do not install the inverter on flammable construction material.
·
Do not install the inverter in areas where highly flammable materials are stored
·
Do not install the inverter in potentially explosive areas.
·
Do not install the inverter during periods of precipitation or high humidity (>95%);
Moisture trapped within the location may cause corrosion and damage to the
electric components.
·
Provide adequate ventilation when using batteries, and read the warning label
on the bottom of the inverter.
·
Install the inverter in a location that maintains an ambient air temperature that is
less than 40°C; That is to maintain a safe internal component temperature: the
inverter would reduce power if the ambient air temperature exceeds 40°C, the
inverter should be installed in a location that is not accessible for children.
·
The inverter emits a slight vibrating noise when operating, which is normal and
no effect on performance.
·
The slope of the wall should be 5°.
·
The inverter is heavy, ensure the mounting place is strong enough to hold the
weight of the inverter;
Содержание BRE-I-5K
Страница 1: ...1 User Manual BRE I 5K OLIPOWER ENERGY AUTOMATION TECHNOLOGY...
Страница 28: ...28 1 ADD Interface ADD interface PINS definition...
Страница 33: ...33...
Страница 34: ...34...
Страница 51: ...51 6 3 5 System Switch Press up or down button to turn on or turn off the inverter Press OK to confirm...
Страница 54: ...54 Reactive power setting After user log into the system Remote control Reactive power...
Страница 55: ...55 Volt watt setting After user log into the system Remote control Australia...
Страница 62: ...62...