40
PV Cnf Fault
PV Connection Setting Fault
·
Resetting the PV connection
·
Or seek help from us, if cannot go back to normal state.
Bat Low Fault
The battery power is low.
·
Wait the battery to be recharged
·
Or seek for help from us.
ByPassRelayFault
By pass relay fault
·
Disconnect PV, grid, and battery, then reconnect
·
Or seek help from us, if not go back to normal state.
SPI CommFault
The communication between master and slave fault
·
Disconnect solar power PV+ PV- and battery, reconnect them.
·
Or seek help from us, if cannot go back to normal state.
BMS_Lost
The communication between BMS and inverter is interrupted.
·
Check if the communication cable between BMS and inverter is
correctly and well connected.
Inter Fan Fault
Fan Device Fault
·
Disconnect solar power PV+, PV- and battery, reconnect them
·
Check if the fan is stopped by dust or other foreign.
·
Or seek help from us, if cannot go back to normal state.
AC HCT Fault
AC Current Sensor Fault
·
Disconnect solar power PV+ PV- and battery, reconnect them.
·
Or seek help from us, if cannot go back to normal state.
InV EEPROM Fault
The master eeprom is fault.
·
Disconnect PV, grid, and battery, then reconnect.
·
Or seek help from us, if not go back to normal state.
GFCIHW Fault
The residual current circuit is fault.
·
Please check if the insulation of electric wires is damaged.
·
Wait for a while to check if back to normal.
·
Or seek for help from us.
EPS Relay Fault
The EPS relay always keep open.
·
Disconnect PV, grid, and battery, then reconnect.
Содержание BRE-I-5K
Страница 1: ...1 User Manual BRE I 5K OLIPOWER ENERGY AUTOMATION TECHNOLOGY...
Страница 28: ...28 1 ADD Interface ADD interface PINS definition...
Страница 33: ...33...
Страница 34: ...34...
Страница 51: ...51 6 3 5 System Switch Press up or down button to turn on or turn off the inverter Press OK to confirm...
Страница 54: ...54 Reactive power setting After user log into the system Remote control Reactive power...
Страница 55: ...55 Volt watt setting After user log into the system Remote control Australia...
Страница 62: ...62...