6 Maintenance
6.1 Burner maintenance
Installation, commissioning, or service of the appliance is to be carried
out by authorized and trained personnel only, adhering to all local
regulations and requirements.
Fasten all safety covers, enclosures, and guards with all screws before
start-up. Use appropriate tools.
Cut off power supply to burner and close manual shut-off valves always
before any maintenance work. Cutting power is adequate when just
inspecting the device.
To maintain flawless operation, do the following at least once a year:
1. Check burner head extension, and change if necessary.
2. Check diffuser disc, and change if necessary. Check burner adjustments if diffuser
disc appears oily.
3. Check ignition cable condition from the whole length. Change, if necessary.
4. Clean and check ignition electrodes, and check correct position. Change, if
necessary.
5. Change oil nozzle if it is worn out or damaged.
6. Check flame detector position, condition and cleanness.
7. Clean filters at least once a year. Filters may have to be cleaned more often
depending on circumstantial conditions.
8. Check air dampers fixing screws and servomotor axle lock. Retighten if necessary.
9. Check and lubricate adjustment rod joints.
10. Check oil pump capacity.
11. Clean burner from dust and moisture.
12. Check gas pipings for leaks.
13. Check combustion characteristics by flue gas measurements regularly or when
sooting boiler.
14. Check regularly combustion characteristics by flue gas measurements, after refilling
storage tank or at least once a year.
15. Check if oil tank needs to be cleaned. Oil tank must be cleaned at least every 4–5
years.
Recommended maintenance
Accurate installation, and adjustments, as well as regular maintenance ensure correct
burner operation.
Correct installation, adjustments, and regular maintenance ensure trouble-free burner
operation.
106 (129)
M5178 1647EN
Содержание GKP-350 M
Страница 2: ......
Страница 5: ...6 15 Burner part list 129 M5178 1647EN 3 129...
Страница 6: ...4 129 M5178 1647EN...
Страница 18: ...Block diagram of contact links Block diagram ver 5 16 129 M5178 1647EN...
Страница 100: ...5 5 Time sequence diagram gas use Time sequence diagram G ver 3 98 129 M5178 1647EN...
Страница 101: ...Time sequence diagram Gp1 ver 5 M5178 1647EN 99 129...
Страница 132: ...130 129 M5178 1647EN...
Страница 133: ......