Device settings → Hot water → Settings → Legionella inhibition
Status view → Hot water → Settings → Legionella inhibition
Time between starts
The interval between heating periods. This interval depends on the domestic hot
water temperature setting.
●
Typical setting: 3–7 days
● With lukewarm domestic hot water, use a shorter interval.
Inhibit start time
The time of day when the function is activated. Select a time when domestic hot
water is not typically used, such as nighttime hours.
Time to next start
The number of days (d) before the function is activated again.
3.5 Other settings
Device settings → Usage info
This option shows usage information across the unit’s entire operating history as well as for the current
year and the previous three full years.
Heating
An estimate of the space heating energy produced.
Hot water
An estimate of the energy produced for heating domestic hot water.
Electricity
An estimate of the compressor’s and the electric heater’s power consumption.
Additional heating
An estimate of the electric heater’s power consumption.
Compressor running
time
The number of hours the compressor has been in operation.
Compressor times
started
The number of times the compressor has started.
Device settings → Usage info → Current year
Heating
An estimate of the space heating energy produced within the current year.
Hot water
An estimate of the energy produced for heating domestic hot water within the current
year.
Electricity
An estimate of the compressor’s and the electric immersion heater’s power
consumption within the current year.
History
The above information shown for the previous three full years, broken down by the year.
Device settings → Heating circuits
See section
Heating.
Device settings → Hot water
See section
Domestic hot water.
Device settings → Operating mode
Off
The heat pump’s compressor and electric immersion heater are off.
In use
The heat pump is on. The electric immersion heater can also be used (if allowed by
the operating mode).
Heat pump
Additional heater only
Only the unit’s internal electric immersion heater is used for heating. The
compressor and the brine circuit are not in use.