![Oilon EasyAce Скачать руководство пользователя страница 10](http://html1.mh-extra.com/html/oilon/easyace/easyace_operation-manual_3564434010.webp)
When active, the setting moves the circuit's heating curve by moving each of the
curve’s points up or down by the selected value. This has the same effect as moving
the curve sideways. If you change the curve manually, the increase or decrease in
heating will be reset.
As changes in room temperature are slow, change the setting by one or two degrees at
a time. Wait for one or two days for the change to become noticeable.
Use cases
Too cold → Increase heating (+)
Too hot → Decrease heating (–)
Radiator heating, guideline values
Floor heating, guideline values
Room tempe1 °C → Increase by 6 (+6)
Room temperature −1 °C → Decrease by 6 (−6)
Room tempe1 °C → Increase by 3 (+3)
Room temperature −1 °C → Decrease by 3 (−3)
1. Tap the icon in the middle of the house. The
change will apply only to the selected heating circuit.
● In the figure,
Circuit 1
has been selected.
2. Increase or decrease the setting, and tap
OK
.
Heating circuits with room temperature measurement
If a heating circuit has room temperature measurement available, the circuit’s
room temperature setting will be displayed in the
Home
view. If room temperature
optimization is also enabled, you can change the
Room temperature setpoint
(target
value). This setting will change the circuit’s flow temperature indirectly.
8 (49)
M8004 2308EN