Maintenance and repair
6.2 Maintenance
6.2.1 Before starting maintenance work
WARNING
Risk of crushing by the clamp pincer
Clamp pincer CP 10 / CP 20 / CC 20 is only completely disconnected from power when the battery is
removed.
Before performing maintenance work, remove the battery of clamp pincer CP 10 / CP 20 / CC 20.
6.2.2 After completion of maintenance work
•
Check all screw connections.
•
Reattach all safety equipment immediately.
•
Check all functions of clamp pincer CP 10 / CP 20 / CC 20.
•
Calibrate clamp pincer CP 10 / CP 20 / CC 20.
6.2.3 Weekly maintenance work
Pincer head
The rollers, plunger and pin on the pincer head are subject to mechanical loading. They must be lubricated at
least once a week when clamp pincer CP 10 / CP 20 / CC 20 is in regular use.
Recommended lubricant:
Description
Type
Manufacturer
Grease
RENOLIT LX EP 2 (RENOLIT DURAPLEX EP 2)
FUCHS PETROLUB AG
Friesenheimer Str. 17
D-68169 Mannheim
Telephone No. +49 (621) 38 02-00
Fax
+49 (621) 38 02-1 90
www.fuchs-oil.de
Tab. 1:
Recommended lubricant
Issue 11.15
08902961
6-32