Clamp pincer CP 10 / CP 20 / CC 20
8
Attachment
8 Attachment
8.1
General information in event of faults
If the closure operation of clamp pincer CP 10 / CP 20 / CC 20 does not start or does not operate correctly,
consult maintenance personnel responsible for clamp pincer CP 10 / CP 20 / CC 20.
8.2 Clearing
faults
If a fault occurs, the clamp pincer will be blocked. The service LED lights up red or orange. Operation can be
restarted only by briefly removing the battery and reinserting it ("reset").
If after the clamp pincer have been “reset” the fault is still present, contact your OETIKER contact person.
8.3
Error messages and troubleshooting measures
INFO
Closing-relevant error messages can be read out with PC software (individual or multiple report).
Please send the respective reports to your OETIKER contact person.
Service LED
Fig. 37:
Service LED
Display after the pressing operation
Cause / remedy
lights up green
Closing force OK.
flashes green/red
Closing force OK, service interval exceeded.
Have the device serviced.
lights up red
Closing force
incorrect
or hardware error
Recalibrate the device. Repeat the joint. Contact Service
Center if necessary.
Issue 11.15
08902961
8-46