TUF-2000F User Manual
31
DIN(cr)
Return net totalizer
±dddddddE±d(cr)
DIE(cr)
Return net thermal energy totalizer
±dddddddE±d(cr)
DIE+(cr)
Return positive energy totalizer
±dddddddE±d(cr)
DIE-(cr)
Return negtive energy totalizer
±dddddddE±d(cr)
DIT(cr)
Return net total flow for today
±dddddddE±d(cr)
DIM(cr)
Return net total flow for this month
±dddddddE±d(cr)
DIY(cr)
Return net total flow for this year
±dddddddE±d(cr)
DID(cr)
Return the ID number/address
ddddd
(cr) 5 bytes long
E(cr)
Return instantaneous Caloric Value
±d.ddddddE±dd(cr)
DL(cr)
Return signal strength and signal quality
UP:dd.d,DN:dd.d,Q
=dd(cr)
DS(cr)
Return the percentage of AO output
±d.ddddddE±dd(cr)
DC(cr)
Return present error code
Note
3
DA(cr)
OCT and RELAY alarm signal
TR:s,RL:s
(cr)note 4
DT(cr)
Return the present date and time
yy-mm-dd,hh:mm:ss
(cr)
Time@TDS1=(cr)
Set date and time
yy-mm-dd,hh:mm:ss
M@(cr)
Send a key value as if a key is pressed.
@ is the key value
M@(cr)
note 5
LCD(cr)
Returns current window content
LOCK0(cr)
Unlock the system
Has nothing to do with the original
password.
LOCK1(cr)
Lock the system
Can be opened by press ENT key
MENUXX(cr)
Go to window XX
LanguageX
(cr)
Select interface language
X=0 for English, 1 for Chinese
2 for Italy, if applicable
3 for Korea, if applicable
4 for French, if applicable
5 for Germany
,
if applicable
6 for Spanish, if applicable
BaudRateX
(cr)
Change baud rate
X=0~7, will set to 19200, 14400,
9600,4800,2400,1200,600,300
C1(cr)
OCT
close
C0(cr)
OCT open
R1(cr)
RELAY(OCT2) close
R0(cr)
RELAY(OCT2) open
FOdddd
(cr)
Force the FO to output a frequency of
dddd HZ
Fdddd
(cr)(lf)