TUF-2000F User Manual
29
3339-3340
2
Total working time
LONG
3341-3342
2
Net total flow for the
month
REAL4
1
3343-3344
2
Net total energy for the
month
REAL4
。。。。
。。。。。。。。。。
。。。。。。
。。。。。。。。。。。。。。 。。。。。。 。。。。。。。。。。。。。。。。。。。。
31
3577-3584
8
Data block No. 31
(3) There is no direct data for the year, data for the year could be conducted from the data of
the months.
5.1.3 REGISTER for power-on and power-off
With every t power-on and power-off, the new generation flow meter will record data about the
time, duration, statue byte and the flow rate into a data block. Every data block consists 32
bytes of data.
There are as many as 16 blocks of data can be recorded, for 16 times of power-on and 16
times of power-off. The data blocks are in a structure of loop queue. The 16th data block will
override the first block by default. The location of the current block is presented in the data
pointer. The current power-on data block is pointed by the decease by 1 of the pointer.
MODBUS registers table for the power-on and power-off.
Block No.
Register
No
.
Variable
Format
Note
n/a
0164
1
Pointer
Integer
Range:
0~31
3585
1
Power-on second and
minute
BCD
Second in low byte, minute in high
3586
1
Power-on hour and day
BCD
Hour in low byte, day in high
3587
1
Power-on month and
year
BCD
Month in low byte, year in high
3588
1
Power-on error code
BIT
B15 stand for corrected lost flow.
3589
1
Power-off second and
minute
BCD
Second in low byte, minute in high
3590
1
Power-off hour and day
BCD
Hour in low byte, day in high
3591
1
Power-off month and
year
BCD
Month in low byte, year in high
3592
1
Power-off error code
BIT
B15 stand for corrected lost flow
3593-3594
2
Flow rate when power
on
REAL4
Flow rate after 60 seconds when
power on
0
3595-3596
2
Flow rate when power
off
REAL4