EX Series Operating Manual
OUTP?
Confirm the power supply's DC output ON or OFF state.
Return value " 0 "
Output off state.
" 1 "
Output on state.
ex) outp?
return value "1"
KEYL {OFF|ON}
This command is controlling the front panel's key/encoder knob locking or unlocking.
> ON
Key locking.
> OFF
Key unlocking.
ex1) keyl on
Key locking.
ex2) keyl off
Key unlocking.
ex2) keyl off
Key unlocking.
KEYL?
Confirm controlling the front panel's key/encoder knob locking or unlocking state.
Return value " 0 "
Output off state.
" 1 "
Output on state.
ex) keyl?
return value "1"
*IDN?
This command is confirming the power supply's properties. You will receive 3 kinds properties.
Return value "ODA Technologies,EX-Series,1.3-1.3-1.2"
First,
Manufacturer.
Second,
Products model.
Third,
Products detailed version.
First,
System controller Version
First,
System controller Version
Second,
Front panel Version
Third,
SCPI protocol Version
ex) *idn?
return value "ODA Technologies,EX-Series,1.3-1.3-1.2"
*SN?
Confirm the power supply serial number.
R t
l
" d
00 0000 00000"
Return value "oda-00-0000-00000"
ex) *SN?
return value "oda-01-0923-00185"
*SAV {1|2|3|4|5|6|7|8|10}
This command is saving the power supply's voltage, current, OVP, OCP Level value in the
non-volatile memory of 1~10.
> 1 ~ 10
Memory saving sector number.
> 1 10
Memory saving sector number.
ex) *sav 2
Save to number 2 memory sector.
- 97 -
Содержание EX 10000
Страница 2: ......
Страница 104: ...EX Series Operating Manual 104...
Страница 105: ...EX Series Operating Manual 105...
Страница 107: ...EX Series Operating Manual 2U 2 6KW 5KW Product Outside Dimension 2U 2 6KW 5KW Product Rear Feature 107...
Страница 108: ...EX Series Operating Manual 4U 5 1KW 10KW Product Outside Dimension 4U 5 1KW 10KW Product Rear Feature 108...
Страница 113: ...EX Series Operating Manual Reliability Durability Life time Test System Solution 113...