EX Series Operating Manual
TTL positive shutdown or turn on
By using TTL signal, you can control the power supply's output On/OFF.When the TTL signal
is hign, output is on, on the contrary, if the TTL signal is low, output is off.
< Figure. 4-9 TTL Positive shutdown or turn on >
TTL Negative shutdown or turn on
By using TTL signal, you can control the power supply's output On/OFF.When the TTL signal
is hign, output is off, on the contrary, if the TTL signal is low, output is on.
< Figure. 4-10 TTL Negative hutdown or turn on >
R
t O t
t C
t l
tti
Remote Output Control setting
The factory default is set as local mode. If device is equipped with option, you should change
the setting and when you use this function, you can not use output key on the front panel.
ODA Techonologies provides total 5 type control included local m, so you must choose
the one of those. Therefore, if you want to control on the front panel, you must choose
Note
the one of those. Therefore, if you want to control on the front panel, you must choose
local mode.
▌Turn on the power supply
After turned on, check the power supply displays"
**OUTPUT OFF**
" Mode.
▌Press the limit display key and hold 3 seconds.
LCD Display
1. V PROG
▌Press the cursor key to move to "OUTPUT METHOD".
LCD Display
3. OUTPUT METHOD
- 60 -
Содержание EX 10000
Страница 2: ......
Страница 104: ...EX Series Operating Manual 104...
Страница 105: ...EX Series Operating Manual 105...
Страница 107: ...EX Series Operating Manual 2U 2 6KW 5KW Product Outside Dimension 2U 2 6KW 5KW Product Rear Feature 107...
Страница 108: ...EX Series Operating Manual 4U 5 1KW 10KW Product Outside Dimension 4U 5 1KW 10KW Product Rear Feature 108...
Страница 113: ...EX Series Operating Manual Reliability Durability Life time Test System Solution 113...