REM:OUTP {LOC|CONT|DIR|TTLP|TTLN}
This command is P/S output ON/OFF command. There are local mode control or 4 types
external control.
> LOC
Local mode controlling. You must choose it when you use RS232 or etc.
> CONT
By using external contact recovery switch, you can control the output ON/OFF.
> DIR
By using external contact state switch, you can control the output ON/OFF.
> TTLP
By external TTL signal, you can control the output ON/OFF.
y
g
, y
p
/
High signal means output is ON.
> TTLN
By external TTL signal, you can control the output ON/OFF.
Low signal means output is ON.
ex) Rem:Outp DIR
You can choose direct switch programming
REM:OUTP?
This command is checking the P/S output ON/OFF control method
This command is checking the P/S output ON/OFF control method.
Return value
"LOC"
Current state is local mode
"CONT"
Current state is contact switch
"DIR"
Current state is direct switch
"TTLP"
Current state is TTL signal positive
"TTLN"
Current state is TTL signal negative
ex)Rem:Outp?
return value "DIR"
)
p
REM:PAR {MAST|SLAV}
This command is choosing command between master P/S and slave P/S when you make
a parallel composition with several P/S.
> MAST
You set this P/S to master.
> SLAV
You set this P/S to slave.
ex) Rem:Par MAST
You set this P/S to master
ex) Rem:Par MAST
You set this P/S to master
REM:PAR?
This command is checking the P/S state between master and slave.
Return value
"MAST"
Current state is master
"SLAV"
Current state is slave
ex)Rem:Par?
return value "MAST"
)
- 92 -
Содержание EX 10000
Страница 2: ......
Страница 104: ...EX Series Operating Manual 104...
Страница 105: ...EX Series Operating Manual 105...
Страница 107: ...EX Series Operating Manual 2U 2 6KW 5KW Product Outside Dimension 2U 2 6KW 5KW Product Rear Feature 107...
Страница 108: ...EX Series Operating Manual 4U 5 1KW 10KW Product Outside Dimension 4U 5 1KW 10KW Product Rear Feature 108...
Страница 113: ...EX Series Operating Manual Reliability Durability Life time Test System Solution 113...