Miscellaneous
NIC configuration
This section specifies the required NIC configuration and related consequences. The SMB
protocol relies on the TCP/IP protocol. In the table below, the settings are split into two
categories. The categories depend on their permanency:
• Commutable settings are used to enable/disable the connection.
Note:
In SMB-support-disabled mode, no communication is possible via the TCP and UDP
ports. Even if TCP and UDP ports are opened permanently at installation.
• Permanent settings are set permanently.
The connectivity settings
Connectivity configuration requirements
Commutable (start-up)
Item
State
Comments
TCP 139
Opened
UDP 137
Opened
UDP 138
Opened
TCP 445
Filtered
IP security policy
UDP 445
Filtered
IP security policy
Permanent (install
time)
Printers and file shar-
ing for Microsoft Net-
works
Disabled
TCP/IP protocol
Enabled
NETBIOS over TCP/IP
Disabled
Located in advanced
parameter of 'TCP/IP'
NwLink NetBIOS
Disabled
NETBEUI
Disabled
Digital signature
The controller supports requests from many SMB clients, but it does not accept the 'Digital
Signature' feature. If option 'Digital Signature' is set to 'always' in the policy, clients cannot
communicate with the OCESMBD. The policy can be local or retrieved from the network domain
controller.
Security
The SMB functionality does not rely on any Microsoft OS SMB layer. The PRISMAsync controller
has its own SMB server and has none of the Microsoft SMB related vulnerabilities.
Network requirements
• Visibility in a workgroup
To see the hostname of the controller in a workgroup at least one other Windows PC must
belong to the same workgroup. This Windows PC has the role of Master Browser.
For example, the hostname can be OCE.
• Name resolution
Miscellaneous
Chapter 11 - SMB printing
301
imagePRESS C7010VPS series v2.2
Содержание imagePRESS C7010VPS series
Страница 8: ...Contents 8 imagePRESS C7010VPS series v2 2...
Страница 9: ...Chapter 1 Introduction...
Страница 14: ...Supported media 14 Chapter 1 Introduction imagePRESS C7010VPS series v2 2...
Страница 15: ...Chapter 2 PRISMAsync...
Страница 29: ...Chapter 3 The LPD connection...
Страница 45: ...Chapter 4 The socket connection...
Страница 51: ...Chapter 5 Adobe PostScript 3...
Страница 64: ...Bind 64 Chapter 5 Adobe PostScript 3 imagePRESS C7010VPS series v2 2...
Страница 86: ...Staple 86 Chapter 5 Adobe PostScript 3 imagePRESS C7010VPS series v2 2...
Страница 89: ...Trim Chapter 5 Adobe PostScript 3 89 imagePRESS C7010VPS series v2 2...
Страница 98: ...List of available and optional fonts 98 Chapter 5 Adobe PostScript 3 imagePRESS C7010VPS series v2 2...
Страница 99: ...Chapter 6 PDF...
Страница 117: ...Chapter 7 Colour management...
Страница 132: ...PDF X output intent with composite output profiles 132 Chapter 7 Colour management imagePRESS C7010VPS series v2 2...
Страница 133: ...Chapter 8 Accounting...
Страница 150: ...Implementation aspects 150 Chapter 8 Accounting imagePRESS C7010VPS series v2 2...
Страница 151: ...Chapter 9 SNMP...
Страница 159: ...Example in pseudo code Chapter 9 SNMP 159 imagePRESS C7010VPS series v2 2...
Страница 222: ...ppmPortGroup 222 Chapter 9 SNMP imagePRESS C7010VPS series v2 2...
Страница 223: ...Chapter 10 JDF interface specification...
Страница 291: ...Basic JDF ticket Chapter 10 JDF interface specification 291 imagePRESS C7010VPS series v2 2...
Страница 297: ...Chapter 11 SMB printing...
Страница 303: ...Chapter 12 Hot folder printing...
Страница 306: ...Hot folder 306 Chapter 12 Hot folder printing imagePRESS C7010VPS series v2 2...
Страница 307: ...Chapter 13 Scan to file and scan to email...
Страница 313: ...Chapter 14 SRA IPDS...
Страница 356: ...Differences between TP and DP colour management 356 Chapter 14 SRA IPDS imagePRESS C7010VPS series v2 2...
Страница 361: ......