NXP Semiconductors
UM11134
FRDMGD3100HBIEVM half-bridge evaluation board
UM11134
All information provided in this document is subject to legal disclaimers.
© NXP B.V. 2020. All rights reserved.
User guide
Rev. 3 — 10 February 2020
28 / 35
6.3.6 Single command
The Single command view contains a log of recent commands, displayed in hexadecimal
format. Single SPI commands can be saved and recalled by name. Commands defined
here are available for scripting in the Batch commands page. SPI words sent and
received (initiated from any tab) are logged here in hexadecimal and can be saved and
exported in a text file. Daisy-chain length command structure (n*24 bit length, where n >
1) are not supported by this view.
Figure 20. Single command view
6.3.7 Batch command
The Batch commands view allows creation of scripts containing commands defined by
the Single command page. Batches can be named, saved, and recalled. This is useful for
quickly initializing the device after powering up.
The batch commands sent can be logged and saved in a text file. The SPI words sent/
received can be viewed in hexadecimal and exported back in the Single commands view.
Daisy-chain length command structure (n*24 bit length, where n > 1) are not supported
by this view.