4.4.4 Signal related jumpers and configuration
Figure 6. Signal related jumper locations
Table 5. Signal related jumper configurations
Jumper
Reference
designator
Position
Function
1-2
MCU/software controls VCC/VEE power supply
2-3
VCC/VEE power supplies always enabled. MCU
control signal is disconnected (default).
PS_EN
J25
Open
Passive pulldown (R14) disables VCC/VEE power
supplies
1-2
Separate CSBH and CSBL. Use for normal mode
(default)
2-3
CSBH and CSBL tied together. Use for daisy chain.
CSB
J34
Open
Not allowed. Only CSBL will be active, not
recommended for normal use.
1-2
MISOL is passed directly to MCU. Use for normal SPI
mode. (default)
2-3
MISOL is passed to MOSIH. Use for daisy-chain SPI
mode.
MISO
J35
Open
Not allowed. MISOL is not routed anywhere for valid
communication.
Closed
MOSIH is routed directly to MCU. Use for normal SPI
mode (default)
MOSI
J30
Open
MOSIH receives MISOL signal. Use for daisy-chain
SPI mode.