Save your settings to flash using the
saveenv
command so that it can be used after reboot.
Use the
edit
command to edit any Environment variable when it is already present, else use setenv for first time.
Edit command usage:
edit eth1addr
and press
Enter, the initial value of the variable will be displayed that can
be edited. Press
Enter after the new value is set.
NOTE
6. Open the prior downloaded tool tftp64 and make sure the IP address assigned to the eth port connected to MPC-LS
VNP EVB is visible in
Server interfaces. (Image shown after step 7)
Note: Add the tftp port to windows firewall settings if not already done. To add go to windows firewall -> advanced settings
-> inbound rules, Right-click on inbound rule and select new rule option, select port option select port, click next and select
UDP and mention 69 as the port number, give TFTP name to it.
7. Make sure the directory that is mentioned in the tftp “Current directory” has the kernel image “kernel-ls1043a-rdb.itb”
provided along with this package.