17. Give a new name to the board and click on
OK. The new board will now come at the top of the board list.
Figure 16. Target Connections window
18. Double-click on your new board name
MPC-LS-VNP-EVB, the Target Connection Configuration window will open
up on the left hand side. First make sure the device selected is
LS1043A, then change the timeout (seconds) to “60”.
Now change the tab to
Target Initialization File.
Figure 17. Configuring the Target Connection
19. In the
Target Initialization File tab, set “USE_SAFE_RCW” to “True” and change the value of “BOOT_CHIP_SELECT”
to 2.
Figure 18. Specifying the options in the Target Initialization File tab
20. Save the configurations by using the
Ctrl + S key combination.
NXP Semiconductors
How to flash the board or perform board recovery
MPC-LS Vehicle Network Processing Evaluation Board User Manual, Rev. 0, Feb 2019
User's Guide
73 / 107