Over The Air Programmer Demonstration
MC1322x SMAC Demonstration Application User’s Guide, Rev. 1.3
10-12
Freescale Semiconductor
4. Once the OTAP Programmer Board finds a device, press SW3. The OTAP Programmer shows the
device address (ID) on the screen. In this case, the device address is 0x01 as shown in
Figure 10-19
.
If more OTAP-Enabled devices were found, press SW3 to see the device IDs.
Figure 10-19. LCD OTAP Devices Screen
5. Press SW4 and the OTAP Programmer flashes the device over the air. Users must wait for the
Program Success message to appear in the serial terminal window and must not press any buttons
on the OTAP Programmer Board or on the device being flashed. The Program Success message is
shown in
Figure 10-20
.
Figure 10-20. LCD OTAP Program Success Screen
10.6
Verifying the Transmitted Image
To verify that the image transmitted by the OTAP Programmer is correct, search for the device using the
OTAP programmer board. If the OTAP Programmer finds the board again, then the application was
correctly flashed.
In this example, the original application loaded on the target board was the Accelerometer Demonstration.
The new application flashed to the target board by the OTAP Programmer was the Wireless UART
Demonstration. After reprogramming, Wireless UART operation can be verified as described in
Chapter 2,
“Wireless UART Demonstration”
.