Generating an SMAC Application and Port Configuration
MC1322x SMAC Demonstration Application User’s Guide, Rev. 1.3
1-4
Freescale Semiconductor
5. Modify the project properties as shown in
Table 1-1
.
Table 1-1. Software Component Properties
Component
Property
Description
SMAC
Security Enabled
Enables the security Module to automatically encrypt the
information sent and received.
Promiscuous Mode
If set to true, the SMAC Code Bytes are not sent prior to the
message.
Security Type
This is the security engine used if the security enabled property
is true.
Security Default KEY0
Less Significative 32 bit Word of the 128 bits to be used as key
on the ciphering engine.
Security Default KEY1
Second Significative 32 bit Word of the 128 bits to be used as
key on the ciphering engine.
Security Default KEY2
Third Significative 32 bit Word of the 128 bits to be used as key
on the ciphering engine.
Security Default KEY3
More Significative 32 bit Word of the 128 bits to be used as key
on the ciphering engine.
Security Default COUNTER0 Less Significative 32 bit Word of the 128 bits to be used as initial
counter on the ciphering engine.
Security Default COUNTER1 Second Significative 32 bit Word of the 128 bits to be used as
initial counter on the ciphering engine.
Security Default COUNTER2 Third Significative 32 bit Word of the 128 bits to be used as
initial counter on the ciphering engine.
Security Default COUNTER3 More Significative 32 bit Word of the 128 bits to be used as
initial counter on the ciphering engine.
PLM
Target hardware
Allows board selection.
LCD Enabled
Includes support for LCDs.
Default SCI Port
Selects the SCI port. Freescale ZigBee boards usually have
SCI Port 1 connected to a DB9 connector and SCI port 2
connected to a USB connector.
MCU Version
Can select either MC13224 or MC13226.
App
Default Channel
Default starting channel in the application.
Output Power
Initial power output configuration.
Baud Rate
Baud rate to be set at the default SCI port for this application
OTAP Enabled
Enables the OTAP Module to allow over the air programming of
the application.
OTAP Request Code
If the OTAP Module is enabled the application will switch to
OTAP mode when this OTAP Request Code is received.
OTAP Device Id
This ID distinguishes between different devices identified by an
OTAP Programmer.