nVent.com
|
24
Raychem-AR-H58692-ACS30UIT2Programming-EN-1805
TABLE 2.2 CONTROL MODE DESCRIPTION AND INDEX
CONTROL MODE DESCRIPTION
NVENT RAYCHEM
HEATING CABLES
SECTION
NUMBER
PAGE
NUMBER
UNASSIGN
Clears all parameters set for a circuit
NA
3.1
52
HWAT
Opens HWAT design wizard
Variable temperature settings can be assigned using
the 24/7 Scheduler1
HWAT
3.2
52
Frost Heave
Freezer frost heave prevention
Variable temperature settings can be assigned using
the 24/7 Scheduler1
RaySol and MI Heating
cables
3.3
58
Floor Heating
Floor heating applications
Variable temperature settings can be assigned using
the 24/7 Scheduler1
RaySol, MI Heating Cables
and
QuickNet Floor Heating
Mats
3.4
62
Pipe Freeze
Pipe freeze protection applications
XL-Trace
3.5
66
Pipe freeze protection with ambient control
XL-Trace
3.5.1
67
Pipe freeze protection with line control
XL-Trace
3.5.2
71
Pipe freeze protection with PASC2 control
XL-Trace
3.5.3
76
Fuel Oil
Fuel oil flow maintenance applications
XL-Trace
3.6
81
Fuel oil flow maintenance with ambient control
XL-Trace
3.6.1
81
Fuel oil flow maintenance with line control
XL-Trace
3.6.2
85
Fuel oil flow maintenance with PASC2 control
XL-Trace
3.6.3
90
Greasy Waste/TM Greasy waste and other temperature maintenance
control
Variable temperature settings can be assigned using
the 24/7 Scheduler1
XL-Trace
3.7
95
Roof and Gutter
Roof and gutter de-icing applications
IceStop and MI heating
cables
3.8
99
Roof and gutter de-icing with external device
IceStop and MI heating
cables
3.8.1
99
Roof and gutter de-icing with ambient control
IceStop and MI heating
cables
3.8.2
97
Roof and gutter de-icing with bracketed ambient
control
IceStop and MI heating
cables
3.8.3
101
Roof and gutter de-icing with surface temperature
control
IceStop and MI heating
cables
3.8.4
109
Snow Melting
Surface snow melting applications
113
Surface snow melting with external device
113
Surface snow melting with ambient control
116
Surface snow melting with surface temperature
control
120
Temperature
Monitor
Only
Monitors any critical temperature defined by the user N/A
4
124
1 Variable temperature setpoint 24/7 Scheduler is described in Appendix 5.2 24/7 Scheduler.
2 Proportional Ambient Sensing Control (PASC) described in related control mode section and Appendix 5.1 Proportional Ambient
Sensing Control (PASC) Control Mode.
Содержание RAYCHEM ACS-30
Страница 1: ...nVent com 1 Raychem AR H58692 ACS30UIT2Programming EN 1805 PROGRAMMING GUIDE ACS 30 System...
Страница 2: ...nVent com 2 Raychem AR H58692 ACS30UIT2Programming EN 1805...
Страница 139: ...nVent com 139 Raychem AR H58692 ACS30UIT2Programming EN 1805 Fig 5 14 ACS 30 Program Integrator Printout...
Страница 144: ...nVent com 144 Raychem AR H58692 ACS30UIT2Programming EN 1805...