MS51
Dec. 17, 2019
Page
119
of 316
Rev 1.01
M
S51
SE
RIES
TE
CHNICA
L REF
ERE
N
CE MA
NU
A
L
PWMCON0
– PWM Control 0
Regiser
Address
Reset Value
PWMCON0
D7H, all pages, Bit addressable
0000_0000b
7
6
5
4
3
2
1
0
PWMRUN
LOAD
PWMF
CLRPWM
-
-
-
-
R/W
R/W
R/W
R/W
-
-
-
-
Bit
Name
Description
7
PWMRUN
PWM run enable
0 = PWM stays in idle.
1 = PWM starts running.
6
LOAD
PWM new period and duty load
This bit is used to load period and duty control registers in their buffer if new period or duty
value needs to be updated. The loading will act while a PWM period is completed. The new
period and duty affected on the next PWM cycle. After the loading is complete, LOAD will be
automatically cleared via hardware. The meaning of writing and reading LOAD bit is different.
Writing:
0 = No effect.
1 = Load new period and duty in their buffers while a PWM period is completed.
Reading:
0 = A loading of new period and duty is finished.
1 = A loading of new period and duty is not yet finished.
5
PWMF
PWM flag
This flag is set according to definitions of INTSEL[2:0] and INTTYP[1:0] in PWMINTC. This bit
is cleared by software.
4
CLRPWM
Clear PWM counter
Setting this bit clears the value of PWM 16-bit counter for resetting to 0000H. After the
counter value is cleared, CLRPWM will be automatically cleared via hardware. The meaning
of writing and reading CLRPWM bit is different.
Writing:
0 = No effect.
1 = Clearing PWM 16-bit counter.
Reading:
0 = PWM 16-bit counter is completely cleared.
1 = PWM 16-bit counter is not yet cleared.