DSP LASER
34
DSPLSR01EN
characteristics ensuring the efficiency if the electro-hydraulic circuit responsible of the
machine stop are checked at most every 30 operating hours.
12.1.5. Blanking and Exclusion LED
When the operating mode 2 or 3 is selected (see chp. 11.2.2), the YELLOW LED blinks.
12.1.6. LED for OSSD outputs in state ON
When the OSSD outputs are in state ON, this is signalled by the turn-on of the GREEN
LED.
12.1.7. LED for OSSD outputs in state OFF
When the OSSD outputs are in state OFF, this is signalled by the turn-on of the RED LED.
12.1.8. Display of the selection of the operating modes
o
When the operating mode 1 is selected, the REAR BLUE LED, the LOWER CENTRAL
BLUE LED and the FRONT BLUE LED are on.
o
When the operating mode 2 is selected, the LOWER CENTRAL BLUE is on.
o
When the operating mode 3 is selected, the LOWER CENTRAL BLUE LED and the
FRONT BLUE LED are on.
12.1.9. Display of the Synchronism fault
If the synchronism signal (SINC) should be subjected to any type of fault and, in any way,
not be suitable to accomplish its function, this defect would be signalled by the turn-off of all
the LEDs, except for the RED LED which would result on.
12.1.10.
Display of the fault of the operating modes
If more than one signal in state ON should be present at the same time on the three inputs
of the operating modes, the anomaly would be signalled by the turn-on in steady way of the
YELLOW and RED LEDs and, in sequence, of the BLUE LEDs.
Содержание DSP LASER
Страница 2: ......
Страница 4: ......
Страница 48: ...DSP LASER 44 DSPLSR01EN CONNECTION SCHEMES Fig 13 6 scheme of connection with AL1B...
Страница 49: ...DSP LASER DSPLSR01EN 45 Fig 13 7 scheme of connection with AL2B...
Страница 50: ...DSP LASER 46 DSPLSR01EN Fig 13 8 scheme of connection with ALdc...
Страница 51: ...DSP LASER DSPLSR01EN 47 Fig 13 9 scheme of connection without AL module...