background image

DSP LASER 

 

 

18 

DSPLSR01EN 

 

Warning

:

 

This function must be used only when necessary for the type of work 
to  do.  It  is  then  responsibility  of  the  employer  to  check  the  correct 
use of the function and to avoid abusing it. 
Here  below,  some  examples  are  reported  which  could  require  the 
use of blanking.

 

 

  Bend of the boxes with special shapes 

The  bending  of  the classic  box  depends  on  the correct  positioning  of  the  piece  both 
against  the  backgauges  and  centred  with  respect  to  the  punch.  This  centring 
operation generally requires the positioning just before the punch touches the sheet. 
For this reason, it is appropriate the command circuit of the press-brake is realized in 
such  a  way that the  operator can  select the  function  of  automatic  stop  of  the mobile 
table in the speed change point. The piece can be then brought to the current bending 
position. 
A possible reason for the activation of the blanking function is related, for example, to 
a shape of the piece such to forbid the insertion of the piece itself between the tools 
when the punch is still at the speed change point.   
Obviously  these  operating  modes  can  be  exploited  to  execute  bends  only  along  the 
edge  of  the  raised  side  and  not  inside  the  box.  In  this  case,  the  raised  box  would 
intercept  the  central  part  of  the  field,  which  can  be  inhibited  only  during  the  slow 
speed closing movement.   

 

  Little size bends 

The  shape  of  the  detection  area  has  been  designed  in  the  rear  part  just  to  limit  the 
interference  with  the  backgauges.  This  does  not  avoid  that  the  final  position  or  the 
shape of the backgauge could hide the rear part of the detection area. 

 

  Little size pieces 

The  shape  of  the  detection  area  has  been  designed  in  the  front  part just  to  limit the 
interference with the operator. However, a  very little size of  the piece can cause the 
operator’s fingers hide the detection area.  
 

The central part of DSP LASER remains active during the high speed closing movement in 
any operating mode. The hiding of the central area must always cause the stop of the press 
when the closing speed is greater than 10 mm\s. 
For this reason, the central detection area must be slightly moved with respect to the tip of 
the punch towards the rear part of the press. 
 

 

Residual risk

:

 

The  blanking  of  part  of  the  detection  area  can  cause  residual  risks 
(see chp. 11 

Residual risks

) due to the shape of the tool and of the 

piece  under  processing  (e.g.  side  of  the  box).  In  fact,  potential 
dangers  of  squashing  between  the  part  of  the  unprotected  tool  and 
the piece under processing or the die or the backgauges arise. 
The  operator  must  be  informed  about  these  risks.  The  department 
personnel  has  the task  to  evaluate,  according to the  shape  and  the 
installation of the dies and to the bending sequence, the risks and to 
inform, as consequence, the operator, before enabling the operating 
mode by key selector.

 

 

Содержание DSP LASER

Страница 1: ...L INSTRUCTIONS TYPE 4 SAFETY DEVICE WITH VISIBLE LASER EMISSION Revision 1 7 of 29 01 2020 NUOVA ELETTRONICA s n c di Pasqui F C Via Parri ZI Moiano 06062 Citt Della Pieve PG ITALIA UE Tel 39 0 578 29...

Страница 2: ......

Страница 3: ...ate Revision Summary of changes 12 09 2009 1 0 Draft 24 10 2009 1 1 First issue 01 12 2009 1 2 Second issue 10 12 2009 1 3 Third issue 03 02 2017 1 4 Fourth issue 16 03 2017 1 5 Fifth issue 26 11 2019...

Страница 4: ......

Страница 5: ...afety in the working places and to the fire prevention The manual must be kept both by the manufacturer and by the user of the machine with care and in a place such to be immediately available each ti...

Страница 6: ...ormation can cause serious dangers for the operator Residual risk The information signals a risk which had been impossible to eliminate Caution Indicates a situation of possible danger which if not av...

Страница 7: ...works and phenomena not depending on the normal operation e g wrong voltage or frequency values of the mains d repair interventions carried out by persons or Technical Service Centres not authorized...

Страница 8: ...ng principle 15 10 Requirements necessary for the correct use of DSP LASER 16 10 1 Command circuit of the press brake 16 10 1 1 Start and stop 16 10 1 2 Inhibition 16 10 1 3 Operating modes 17 10 1 4...

Страница 9: ...3 Mechanical installation 38 13 3 1 Modules ALdc AL1B AL2B 38 13 3 2 Transmitter and Receiver 38 13 3 3 Setting 40 13 3 4 Installation 41 13 4 Electrical connection 43 14 Commissioning 52 14 1 Power...

Страница 10: ...an overload for the transformer so compromising the correct operation of it and of the circuits for the emission and the reception of the laser beam and as consequence the device control functions Op...

Страница 11: ...e removal of the device 6 6 Spare parts The spare parts can be provided only by Nuova Elettronica 6 7 Decommissioning When you decide not to use the device DSP LASER anymore because obsolete or irrepa...

Страница 12: ...ween the moment when the test piece is inserted in the detection area and the moment when the two OSSD switch to OFF state STATE OFF State where the output circuit OSSD is open and cuts the current fl...

Страница 13: ...of type 4 ISO 13849 1 2015 it can be classified as PL e SIL3 The laser contained in DSP LASER is classified as CLASS 1M according to the rule CEI EN 60825 1 2015 DSP LASER if correctly installed and...

Страница 14: ...ependent microprocessors to implement the function of control of the detection area of command of the outputs and in general of monitoring of the system two safety solid state OSSD switching devices p...

Страница 15: ...minating the receiving elements causes the detection of the occurred interruption The detection of the interruption of one or more of the receiving elements is then managed by the system to issue or n...

Страница 16: ...24Vac AL1B Power supply module with filter and power supply transformer by 220Vac or 24Vac and OSSD outputs with relay AL2B The codes identifying RX module of DSP LASER with the corresponding configu...

Страница 17: ...ting cycle of a bending press brake Here below the operating diagram of the working cycle of a hydraulic bending press brake with closing from above is schematically presented States of the cycle Abbr...

Страница 18: ...n area volume for the protection of the operator who enters in it Warning DSP LASER provides protection to the operator only stopping the movements in progress of the upper table Then it cannot be use...

Страница 19: ...s then clear that the safety area precedes the movement of the upper tool of a such space to allow the tool can be stopped without squashing any opaque object possibly present between it and the lower...

Страница 20: ...of the detection area during the fast approaching phase of the tools speed greater than 10 mm s must stop the closing movement of the table The new closing must take place only after that the operator...

Страница 21: ...ated by us and then protected by means of DSP LASER This function can be then excluded when the protected machine does not need it for example it is provided with a single pair of tools one upper and...

Страница 22: ...he slow speed closing movement Little size bends The shape of the detection area has been designed in the rear part just to limit the interference with the backgauges This does not avoid that the fina...

Страница 23: ...ore operating modes at the same time brings to a condition of lock of the equipment until when the failure has been removed The absence of selection of any operating mode causes the equipment operates...

Страница 24: ...wnstroke of the crossbar is inhibited at the first pressure of the pedal The Blanking function is moreover subjected to a periodical check in order to avoid the machine could be inadvertently left in...

Страница 25: ...The downstroke pedal is released From this moment the blanking function in the front area becomes active If the front area remains obscured presumably by the edge of the box to realize pressing the d...

Страница 26: ...occurs Until part or the entire detection area is obscured the release and the immediate new pressure of the downstroke command cause the machine can continue the closing downstroke at decreased spee...

Страница 27: ...area and the exclusion of the rear area The press brake closes at high speed up to PCV even if one of more elements put in blanking state or excluded are obscured The stop of the machine because the...

Страница 28: ...are identical to those of mode 1 with the only difference that the rear area is excluded The central and front protection areas are active the obscuration of any receiving element of these areas caus...

Страница 29: ...t consider the actuation and release strokes of the limitswitch VSA On the front side of the receiver some LEDs are present signalling during the check of the stop space the state of the signals neces...

Страница 30: ...Fig 10 5 Test not passed Phase A When the machine is switched on the two OSSD relays are in OFF state and do not allow the closing of the machine at high speed the mobile table must be moved to PMSM...

Страница 31: ...ing at high speed is commanded and then the FAST DOWNSTROKE signal which it depends from is present on the relevant input The closing of the press until the interception of the limitswitch VSA must ta...

Страница 32: ...nts the device sets the OSSD outputs to OFF state When the object is not detected any more the outputs return to ON state If the detection of the object takes place with machine in closing then with t...

Страница 33: ...ty of the operator is ensured by the reduced speed combined with a dead man command It is then the operator who aware of the residual risks commands the closing movement of the press In case of manual...

Страница 34: ...ar mechanics The system is provided with operating modes which allow the inhibition of the front and or rear detection area even during the fast approach speed In this way the protection of the front...

Страница 35: ...in training the operators working on the press brakes o Address only qualified operators who have been trained about the adjustment and the use of these machines to this task o Define if necessary som...

Страница 36: ...ints out that the power supply is connected to the transmitter The state of LASER EMISSION absent points out that the power supply device is not energized RECEIVER Fig 12 2 Front side of the receiver...

Страница 37: ...omes back again to ON state because the cam has gone beyond it causing the failure of the check 12 1 2 Display of the alignment with four LEDs In the check phase the PMSM input is set to ON state with...

Страница 38: ...de 1 is selected the REAR BLUE LED the LOWER CENTRAL BLUE LED and the FRONT BLUE LED are on o When the operating mode 2 is selected the LOWER CENTRAL BLUE is on o When the operating mode 3 is selected...

Страница 39: ...the laser beam with optical instruments Fig 12 3 Rear identification plate of TX The following data are reported on the side plate of TX Part of the device DSP LASER TX Serial number and manufacturing...

Страница 40: ...c IN 0 Vdc P and GROUND Connections to TX GROUND OUT 0Vdc P OUT 24V P SINC Connections to RX GROUND OUT 0Vdc P OUT 24V P SINC OSSD1 24Vdc OSSD2 24Vdc Relay outputs NA OSSD contacts OSSD1 CR OSSD1 CR O...

Страница 41: ...art of the device DSP LASER AL Indication of the type of AL that is its configuration Power supply voltage IN 230 Vac or IN 24 Vac and GROUND Connections to TX GROUND OUT 0Vdc P OUT 24V P SINC Connect...

Страница 42: ...equipped for the disposal in the respect of the nature and of the laws Check by sight the presence and the integrity of all the components constituting the device ensuring there are not evident damag...

Страница 43: ...The detection area must be placed under the upper tool The manufacturer of the press has the task to correctly install the device while the user is responsible to correctly adjust the device accordin...

Страница 44: ...the user of the press only in longitudinal direction along the vertical axis For this purpose the manufacturer of the press must realize two plates to be firmly fixed to the table provided with exten...

Страница 45: ...iring the unassembly of the devices and or supports e g possibility to extract the tools with the TX completely lifted The locking of the support once adjusted is safe against the accidental loosening...

Страница 46: ...l the length of the upper tool Fig 13 5 Adjustment longitudinal with respect to the bending line The designing of the mobile support of the device must be such not to create entrapment points during t...

Страница 47: ...y turn on of the following LEDs RED LED VSA LED Blinking of the following LEDs FRONT BLUE LED HIGH CENTRAL BLUE LED REAR BLUE LED and LOW CENTRAL BLUE LED Caution The control of the procedures of star...

Страница 48: ...DSP LASER 44 DSPLSR01EN CONNECTION SCHEMES Fig 13 6 scheme of connection with AL1B...

Страница 49: ...DSP LASER DSPLSR01EN 45 Fig 13 7 scheme of connection with AL2B...

Страница 50: ...DSP LASER 46 DSPLSR01EN Fig 13 8 scheme of connection with ALdc...

Страница 51: ...DSP LASER DSPLSR01EN 47 Fig 13 9 scheme of connection without AL module...

Страница 52: ...connect to OUT 0Vdc of the ALdc module If the AL module is not used connect directly to the negative terminal of the power source which has to supply a 24Vdc voltage The power supply signal OUT 0Vdc...

Страница 53: ...nstead only the inputs High speed in press brake closing IN AV and Press brake opening IN AP shall be connected because used by the Blanking Type B while the signals High speed in press brake closing...

Страница 54: ...r IN 24Vac signals and the GROUND signal must be connected to AL2 SIGNALS Besides the clamps of the signals connected to TX and RX the two power supply IN 230Vac or IN 24Vac signals and the GROUND sig...

Страница 55: ...he press during the dangerous closing movement or in other cases before the next request of intervention of the safety function or at the latest at the end of the operating cycle Moreover the start of...

Страница 56: ...ate OSSD outputs using a tester as voltmeter in cc e measuring between 0Vcc and OSSD1 and then between 0Vcc and OSSD2 When the system configuration is with ALdc or AL2B the check is possible verifying...

Страница 57: ...ower edge of the laser emission coinciding with the line pointing out the highest value 19mm of the STOP SPACE Fig 14 2 Cross view Fig 14 3 Front view Then adjust TX along the surface transversal to t...

Страница 58: ...to the bending line pointed out by the lower edge of the punch with the purpose to obtain at point B the beam position conditions as in point A of Fig 14 3 without changing the vertical and horizonta...

Страница 59: ...stallation of the supports and the mechanical adjustment of the device supposes that at every tool change the tool height is simply adjusted depending on the height of the punch without any interventi...

Страница 60: ...high speed closing keeping the speed constant until the interception of the limit switch VSA as otherwise the device considers the check not passed and sets the OSSD outputs to state OFF The check of...

Страница 61: ...e and the edges of the detection area must be contained within the two surfaces defined by R and F If the above conditions would not subsist and a mechanical adjusting intervention was necessary call...

Страница 62: ...ible to the die For the same reasons the minimum thickness possible of the sheet must be set on the Numeric Control or in alternative a sheet with thickness equal to that set must be put between the d...

Страница 63: ...e device 17 Troubleshooting guide LED PMSM blinks RED LED steady on Check of the stop space failed Error of limitswitch PMSM LED AV blinks RED LED steady on Check of the stop space failed Error due to...

Страница 64: ...om the male one welded on TX those with 12 and 3 poles from the corresponding male ones welded on RX TX and RX are separated from the machine Fig 18 1 Removal of the rear cover If present disconnect e...

Страница 65: ...le 650 nm Beam divergence 0 2 mrad Laser classification class 1 M Dimensions of laser beam at TX output Complex geometrical figure contained in a rectangle area 48mm X 24 mm Maximum operating distance...