Maintenance
•
Cleaning of DSP LASER device
Check that no incrustations, impurities or humidity drops settle on the emission and
detection surfaces respectively of transmitter and receiver. In this case, use a soft and
wet cloth.
Cautions:
•
Do not use toxic or flammable substances
or substances which
can make opaque the front side of TX and/or RX where the
laser beam is emitted and receive
to clean the device.
•
Do not use water on the device.
17.
Troubleshooting guide
LED PMSM blinks
RED LED steady on
Check of the stop space failed.
Error of limitswitch PMSM.
LED AV blinks
RED LED steady on
Check of the stop space failed.
Error due to HIGH SPEED.
LED VSA blinks
RED LED steady on
Check of the stop space failed.
Error of limitswitch VSA. S.A. has become greater.
Turn-on in sequence of LEDs:
RED, GREEN and YELLO/BLUE
DSP LASER with OSSD outputs in state OFF permanently
Because operating from more than 30 consecutive hours.
Only RED LED on
Malfunction or absence of the synchronism signal.
Turn-on in sequence of BLUE LEDs:
RED and YELLOW LEDs on
Malfunction on the inputs of the operating modes.