![NUOVA ELETTRONICA DSP LASER Скачать руководство пользователя страница 59](http://html1.mh-extra.com/html/nuova-elettronica/dsp-laser/dsp-laser_instruction-manual_1717898059.webp)
DSP
LASER
DSPLSR01EN
55
In point B1 of Fig. 14.3, you can see the front side of RX illuminated by a part of the beam
exiting from the SLOT FOR RX HORIZONTAL POSITIONING.
Move RX in horizontal direction in such a way that the light is between the STOPS FOR
THE RX HORIZONTAL POSITIONING, as in Fig. 14.5.
Fig. 14.6 Vertical adjustment of RX
Move the instrument from the lower tool.
Move RX in vertical direction in such a way that the LOWER EDGE OF THE LASER
EMISSION coincides with the STOP FOR THE RX VERTICAL POSITIONING as in Fig.
14.6.
Check that the YELLOW/BLU LED turns on, as confirmation of the occurred alignment.
If not, act on the screws for the adjustment of the parallelism of RX to the bending line
pointed out by the lower edge of the punch, in order to obtain the condition of turn-on of the
YELLOW/BLUE LED, without changing the vertical and horizontal position previously set.
The correct installation of the supports and the mechanical adjustment of the device
supposes that, at every tool change, the tool height is simply adjusted depending on the
height of the punch without any intervention by the user on the cross adjustment and the
parallelism.
Check then the correct alignment first installing the upper tool with minimum height and then
that with maximum height. If the conditions for a correct adjustment would be lacking, it is
necessary to check and, possibly, act on the parallelism of the supports with respect to the
bending surface.
14.3. Check of the stop space
The check must be executed in the worst conditions possible, that is in the state which
presumably generates the maximum stop space. Among these, remember to install the
punch with maximum weight, set the maximum closing speed and the maximum stroke.
Execute the check as described in chp.
15.4 Check of the correct positioning
.
The test must be repeated at least 10 times for every machine. Only the positive result of all
the tests allows considering the press-brake suitable for the installation and use of the
device.
Содержание DSP LASER
Страница 2: ......
Страница 4: ......
Страница 48: ...DSP LASER 44 DSPLSR01EN CONNECTION SCHEMES Fig 13 6 scheme of connection with AL1B...
Страница 49: ...DSP LASER DSPLSR01EN 45 Fig 13 7 scheme of connection with AL2B...
Страница 50: ...DSP LASER 46 DSPLSR01EN Fig 13 8 scheme of connection with ALdc...
Страница 51: ...DSP LASER DSPLSR01EN 47 Fig 13 9 scheme of connection without AL module...